Table 2.1. Functional Specifications < 2 / 2; Table 2.2. Installation Environment Requirements - Contec IPC-PT/L600S(PCW)P User Manual

Pc-pt/x600x(pcw)-hmu seriies
Table of Contents

Advertisement

Overview
Table 2.1. Functional Specifications < 2 / 2 >
Model
Power
Input supply voltage
supply
Current consumption
Expansion board
supplies power
Panel cut dimensions (mm)
Outside dimensions (mm)
Weight
Waterproofing, dustproofing
Dustproof & Waterproof

Table 2.2. Installation Environment Requirements

Parameter
Power supply specifications
Allowable instantaneous
power outage
Dielectric strength
Insulation resistance
Ambient specifications
Operating temperature
Storage temperature
Humidity *1
Floating dust particles
Corrosive gases
Line noise
Line-noise
Static electricity
resistance
resistance
Sweep resistance
Vibration
resistance *2
Fixed-vibration
resistant
Impact resistance *2
Grounding
*1 When a floppy disk is not in use.
*2 When the HDD and FDD are not in use.
8
IPC-PT/L600S(PCW)C, IPC-PT/L600S(PCW)P, IPC-PT/H600X(PCW)C, IPC-PT/H600X(PCW)P
IPC-PT/L600S(PCW)P
IPC-PT/L600S(PCW)C
100 to 120 VAC or 200 to 240 VAC (50/60 Hz): Input automatically selected
95VA(Max.)
50VA(Max.)
+5V:2A(1A × 2 slots),
-5V:Not supplied,
None
+12V:0.3A,
-12V: 80mA
344±0.5(W)×281±0.5(H)
(12 stud holes are required around.)
370(W)×307(H)×139(D)
370(W)×307(H)×79(H)
(Board depth)
(Board depth)
About7.5kg
About6.6kg
IP65, fornt
Front in compliance with IP65
Requirement description
Less than 20ms
One minute each for 3.0 kVAC (input-output), 2.0 kVAC (input-FG),
and 0.5 kVAC (output-FG)
50M Ω (DC500V)
0 to 50ºC(SDD in use)
0 to 45ºC(HDD in use)
5 to 45ºC(FDD in use)
-10 to 60ºC
10 to 90%RH(No condensation)
Not to be excessive
None
AC line/2kV, Signal line/1kV (IEC1000-4-4Level 3, EN61000-4-4Level 3)
Contact discharge/4kV (IEC1000-4-2Level 2, EN61000-4-2Level 2)
Atmospheric discharge/8kV (IEC1000-4-2Level 3, EN61000-4-2Level 3)
10 to 50Hz/semi-amplitude 0.15mm 50 to 500Hz/2.0G
23 min. each in x, y, and z directions
(JIS C0040-compliant, IEC68-2-6-compliant)
30 min. each in x, y, and z directions
(JIS C0040-compliant, IEC68-2-6-compliant)
10G, half-sine shock for 11 ms in x, y, and z directions
(JIS C0041-compliant, IEC68-2-27-compliant)
Class D grounding (previous class 3 grounding)
IPC-PT/H600X(PCW)P
IPC-PT/H600X(PCW)C
95VA(Max.)
50VA(Max.)
+5V:2A(1A × 2 slots),
-5V:Not supplied,
None
+12V:0.3A,
-12V:80mA
398±0.5(W)×306±0.5(H)
(12 stud holes are required around.)
428(W)×336(H)×139(D)
428(W)×336(H)×79(D)
(Board depth)
(Board depth)
About8.5kg
About7.6kg