To Clear All Error Code; To Exit From Self-Diagnostic Function; Power Amplifier Failure (F61); Description Of Error Code - Panasonic SA-AK230GCP Service Manual

Cd stereo system
Hide thumbs Also See for SA-AK230GCP:
Table of Contents

Advertisement

SA-AK23 0GCP
3. Press
4. Press "CD DIRECT PLAY (5)" and
5. Press
6. Press
7. Press "n/STOP" to indicate Error Code.
· If several problem exist, error code will change each time when "n/STOP" is pressed. (e.g. F15 → F26 → F16 ....etc).

12.5. To clear all Error code

1. Press
and hold button for 5 seconds.
2. FL indicator shows "CLEAR" for 1 second and change to "T".

12.6. To exit from Self-Diagnostic function

1. Press
button on main unit or remote control.

12.7. Power Amplifier Failure (F61)

1. When power amplifier fail, F61 will indicate automatically .

12.8. Description of Error Code

12.8.1. Abnormality detection for Deck Mechanism block
No.
Abnormal Items
1
MODE SW abnormal
2
REC INH SW abnormal
3
HALF SW abnormal
4
Reel pulse abnormal
12.8.2. Abnormality detection for CD/Changer block
No.
Abnormal Items
1
REST SW abnormal
2
Transmission error between CD servo
LSI and micon
3
CLAMP SW abnormal
4
BOTTOM SW abnormal
5
POSITION SW abnormal
6
SW1 abnormal
7
SW2 abnormal
8
OPEN SW abnormal
9
CLOSE SW abnormal
10
DISC SENSOR
to close the tray.
wait until the tray is open.
and remove the CD.
to close the tray.
Error Display Method of Detection
H01
H02
H03
F01
Error Display Method of Detection
F15
F26
F16
F17
F27
F28
F29
H15
H16
F30
Normal operation during mecha transition, MODE SW abnormal is
memorized. The content of abnormality can be confirmed in the
abnormal detection mode explained in the later section.
The content of abnormality can be confirmed in the abnormal detection
mode explained in the later section.
The content of abnormality can be confirmed in the abnormal detection
mode explained in the later section.
The content of abnormality can be confirmed in the abnormal detection
mode explained in the later section.
Under normal operation (Self-Diagnostic Mode inclusive), this error
occurs when the REST SW ON is not detected within the specified time
and shall be memorized.
Under normal operation (Self-Diagnostic Mode inclusive), this error occurs
when the selection is set to CD and SENSE='H' is detected and
SENSE='L' is not detected within a fail safe time (20ms) after system
command transmission was sent.
Refer to section 12.8.4 (Mechanism Error Code Table) [M-0A] error is
detected.
Refer to section 12.8.4 (Mechanism Error Code Table) [M-09] error is
detected.
Refer to section 12.8.4 (Mechanism Error Code Table) [M-05 ~ M-08] error
is detected.
Refer to section 12.8.4 (Mechanism Error Code Table) [M-02 ~ M-08] error
is detected.
Refer to section 12.8.4 (Mechanism Error Code Table) [M-02 ~ M-08] error
is detected.
Refer to section 12.8.4 (Mechanism Error Code Table) [M-01] error is
detected.
Refer to section 12.8.4 (Mechanism Error Code Table) [M-01] error is
detected.
Refer to section 12.8.4 (Mechanism Error Code Table) [M-01] error is
detected.
44

Advertisement

Table of Contents
loading

Table of Contents