5-3. Imaging problems (for digital only)

Problem
1. The monitor configuration is changed to
single under the multiple monitor configu-
ration (when DisplayPort is connected).

5-4. Imaging problems (for analog only)

Problem
1. Display position is incorrect.
2. Vertical bars appear on the screen or a
part of the image is flickering.
3. Whole screen is flickering or blurring.
34
Chapter 5 Troubleshooting
Possible cause and remedy
• When two monitors are connected to one PC using
DisplayPort, and the power to one of the monitors is
turned off with the power button, the screen setting may
be changed to the single monitor configuration. In such a
case, enable the "DP HotPlug" function with the following
procedures. Enabling this function may increase the
power consumption.
1.
Press
to turn off the monitor.
2.
Hold down
while pressing
Each time the operation enables / disables this function
alternatively.
The current setting status can be identified based on the
color used to display the input port or signal error.
Setting
Input port
Disable
(default
setting)
Enable
Possible cause and remedy
• Use "Position" in the Setting menu to correct the image
position (see
"To correct the screen position" (page
• If the problem persists, use the graphics board's utility if
available to change the display position.
• Use "Clock" in the Setting menu to adjust it (see
eliminate vertical bars" (page
• Use "Phase" in the Setting menu to adjust it (see
remove flickering or blurring" (page
to turn on the monitor.
Signal Error
21)).
"To
20)).
"To
20)).