Troubleshooting & Diagnostic:
Possible reason:
Freezer
compartment too warm.
Possible reason - On IDI
appliances:
Frozen water incoming tube to the
icemaker.
Possible reason - On NO-IDI
appliances:
Frozen water incoming chute to
the icemaker (see picture).
Note: this issue could be more
frequent in case of water not
filtered (be sure that customer
replaces regularly the water filter).
No ice production
(no ice in the ice container)
To solve this problem, make the rework
procedure as described in the
Bulletin 4812 711 40138.
Check if valve works properly (no leakages and
water quantity filling ok). If valve does not close
completely, change the valve.
Put two sponges (one upper the chute, one on the
rear of the cabinet) as shown in pictures below.
See the 'freezer too warm' chapter.