Air Baffle Failure Indication "D" On The Display - Whirlpool Cassinetta Repair Manual Line

Side by side electronic refrigerator
Table of Contents

Advertisement

Clean damper and
air passages from
Change the damper
- On old appliances (before 2006): prepare the appliances with the
Service Solution "New air baffle cover kit" as described in the
Bulletin 4812 711
- On 2007 and 2008 not Biruni appliances: change the Main Board with a
new one introducing a complete damper sliding door operation (opening-
closing) every 25 minutes, as described in the
40303. Ice formation is avoided by the periodical operations of the air
baffle which are 'cleaning' the slide path.
(*) Note: After 2006 range, the failure indication on the display will be shown only in the first 10 minutes. To
see the indication again, plug out and plug in the appliances.
Troubleshooting & Diagnostic:

Air baffle failure indication "d" on the display (*)

Check if the damper is blocked
Yes
ice
Yes
Visual check of damper
sliding door. Slide is
broken or other defects?
(see also next page)
Damper is OK
40158/2.
by ice formation
Check the connections to the
damper and feedback signal at
the main board (pin 5/12)
No
Service Bulletin 4812 711
No
Connections OK
Check if damper works
(see also next page)
Yes
No
Damper is defect
Change the damper
Service
50