Quarterly; Semi-Annually - Cornelius IMD GLACIER 500-30 Installation Manual

Imd glacier series countertop ice maker
Table of Contents

Advertisement

Quarterly

!
WARNING:
Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all
power is off to the unit before performing any work.
This is the maximum period of time between cleaning and sanitizing the ice maker. In addition to recommended
monthly procedure, and if a more frequent cleaning and sanitizing pattern has not been established, unit must be
cleaned and sanitized.

Semi-Annually

!
WARNING:
Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all
power is off to the unit before performing any work.
Semi-Annually in addition to all previously established service procedures perform the following:
1. Check for water leaks in tube connections, water fittings, and lower ice maker water seal.
2. Check drain tubes for clogs and "aged" tubes. Replace if tubes are stained or brittle.
3. Check for signs of condensation. Clean where necessary and replace insulation properly.
4. Check safety circuits for proper operation.
5. Check refrigeration system.
6. Check unit for abnormal noise. Tighten machine and cabinet screws, if necessary.
7. Check white upper bearings on auger assembly. If bearings are less than 1/16" (0.0625mm) thick, replace.
See Figure 16.
NOTE: Preventive maintenance can increase the trouble-free life of your ice maker. Failure to perform
preventive maintenance could void your equipment warranty.
© 2018, Cornelius Inc.
Figure 16. Upper Bearing and Auger Assembly
- 19 -