Lennox Elite CBX32M-024 Installation Instructions Manual page 9

Cbx32m series multi-position air handler
Hide thumbs Also See for Elite CBX32M-024:
Table of Contents

Advertisement

A IMPORTANT
WARNING
Each unit includes a factory-installed
filter. Note that filter
access door fits over access panel. Air leakage will occur if
access panel is placed over filter door.
Filters should be inspected monthly and must be cleaned
or replaced when dirty to assure proper furnace operation.
Reusable filters supplied with some units can be washed
with water and mild detergent. Some units are equipped
with standard throw-away
type filters which should be
replaced when dirty.
To replace filter:
Step 1.. Loosen the thumbscrews holding the filter panel
in place.
Step 2..
Slide the filter out of the guides on either side of
cabinet.
Step 3..
Insert new filter.
Step 4..
Replace panel.
See table 3 for replacement filter sizes.
Table 3. Filter Dimension
Unit Model No.
Filter Size Inches (mm)
CBX32M018/024
15 x 20 (381 x 508)
CBX32M-030
20 x 20 (508 x 508)
CBX32M-036,042
20 x 22 (508 x 559)
CBX32M-048,060
20 x 24 (508 x 610)
L2 LI
1 L
CIRCUIT 1
,ll
Wiring must conform to the current National Electric Code
ANSI/NFPA
No. 70, or Canadian Electric Code Part I, CSA
Standard
C22.1,
and local
building
codes.
Refer to
following
wiring
diagrams.
See
unit
nameplate
for
minimum
circuit
ampacity
and maximum
overcurrent
protection size.
HEAT ELEMENT _I
CIRCUIT BREAK-
ERS OR TERMI-
NAL BLOCK
Select
the
proper
supply
circuit
conductors
in
accordance
with tables
310-16
and 310-17
in the
National Electric Code, ANSI/NFPA
No. 70 or tables 1
through 4 in the Canadian
Electric
Code, Part l, CSA
Standard C22.1.
This unit is provided with knockouts
for conduit. Refer to
figure
15 for unit schematic
wiring diagram.
Refer to
figures
14 through
13 for typical field wiring.
Separate
openings
have been provided
for 24V low
voltage and line voltage. Refer to the dimension illustration
for specific location.
K3 INDOOR
BLOWER RELAY
TRANSFORMER
K32
CB1
HEAT_RELAY
,I CIRCUIT
_}
BREAKER
OR
GROUND
FUSE
±
,/_ THERMOSTAT
TB,
L._
(D_
__
TERMINALI 0
.
I j
I
I
rj
I
L_
I
"
I
L--
__1
I r
-J
/kvv
NOTE - USE COPPER CONDUCTORS
ONLY.
REFER TO UNIT RATING PLATE FOR MINIMUM
CIRCUIT AMPAClTY AND MAXIMUM OVERCUR-
RENT PROTECTION
SIZE
LINE VOLTAGE FIELD INSTALLED
CLASS 2 VOLTAGE FIELD INSTALLED
NEC/CEC
NOTE - ALL REMAINING WIRES ARE FACTORY
INSTALLED
z_TO
EXTERNAL LOAD 24VAC AT .50 AMP MAXI-
MUM.
Z_ THERMOSTAT
HEAT ANTICIPATION
SETTING 0.4
AMP ELECTRIC HEAT
Z_ WHEN TWO-STAGE THERMOSTAT
IS USED,
CONNECT SECOND STAGE HEAT BULB TO TER-
MINAL "W2" AND REMOVE JUMPER BETWEEN
TERMINALS
"R" AND 'W2."
/2X FACTORY INSTALLED JUMPERS
Z_ L3 CONNECTION
USED ON (Y-VOLTAGE)
3-PHASE ELECTRIC HEATERS ONLY,
Figure 11. Typical Field Wiring - Cooling Application with Electric Heat
Page 9
CBX32M
SERIES

Hide quick links:

Advertisement

Table of Contents