Air Volume Adjustment - Lennox Elite CBX32M-024 Installation Instructions Manual

Cbx32m series multi-position air handler
Hide thumbs Also See for Elite CBX32M-024:
Table of Contents

Advertisement

Seal the unit so that warm air is not allowed into the
cabinet. Warm air introduces moisture, which results in
water blow-off problems. This is especially important when
the unit is installed in an unconditioned area,
Make sure the liquid line and suction line entry points are
sealed with either the provided flexible elastomeric thermal
insulation,
or field
provided
material
(e.g. Armaflex,
Permagum or equivalent). Any of the previously mention
materials
may be used to seal around the main and
auxiliary drains, and around open areas of electrical inlets.
MINIMUM BLOWER SPEEDS (WITH ELECTRIC
HEATERS)
For the minimum allowable speed for the CBX32M series
units with electric heat, refer to the ECB29 installation
instructions.
Table 4.
AIR VOLUME ADJUSTMENT
Blower speed selection is accomplished by changing the
taps at the harness connector
at the Blower motor as
illustrated in figure 16. Refer to unit wiring diagram in figure
15 on page 11. Refer to tables 4 through 9 for air handler
)erformance data,
HARNESS
CONNECTOR
F
PRESS THE TAB TO RELEASE
WIRE CONNECTOR.
SELECT
CONNECTOR
LOCATION
FOR NEW SPEED.
INSERT WIRE UNTIL IT CLICKS.
Figure 16. Blower Speed Tap Selection
CBX32M-018/024
Air Handler
Pe_ormance
(208/230V)
Air Volume and Motor Watts at Specific Blower Taps
Low
Medium
L/s
Wat_
cfm
L/s
Wat_
cfm
330
245
895
425
300
1030
330
245
890
420
295
1015
325
240
875
415
290
1000
320
235
860
405
285
980
315
230
845
400
280
960
310
220
825
390
275
935
300
215
800
380
265
910
280
205
745
355
250
850
255
190
685
320
235
780
220
175
605
285
220
705
185
165
520
245
200
615
165
155
475
225
195
565
unit with air fil_r in place. Ele_ric hea_
have no app_ciable air
Table 5. CBX32M-030
Air Handler
Performance
(208/230V)
Air Volume and Motor Wat_ at Specific Blower Taps
Low
Medium
L/s
Wat_
cfm
L/s
Wat_
cfm
490
315
1175
555
335
1290
505
310
1190
560
330
1295
515
300
1190
560
325
1290
510
295
1175
555
320
1265
505
285
1145
540
310
1230
485
270
1105
520
295
1180
460
255
1045
495
280
1115
390
220
890
420
250
945
290
190
675
320
215
720
155
160
405
190
185
440
unit with airfil_rin
place. Electric hea_
have no app_ciable air
External Static
Pressure
High
in. w.g.
Pa
cfm
L/s
Wat_
.00
0
700
485
365
.05
10
695
480
360
.10
25
690
470
355
.15
35
680
465
345
.20
50
665
455
340
.25
60
650
440
335
.30
75
635
430
325
.40
100
590
400
310
.50
125
535
370
295
.60
150
470
330
280
.70
175
395
290
265
.75
185
350
265
255
NOTE - All air dab is measu_d external
_sis_nce.
External Static
Pressure
High
in. w.g.
Pa
cfm
L/s
Wat_
.00
0
1045
610
385
.05
10
1075
610
380
.10
25
1085
610
375
.15
35
1085
600
370
.20
50
1065
580
360
.25
60
1030
555
350
.30
75
980
525
335
.40
100
830
445
305
.50
125
615
340
275
.60
150
335
205
240
NOTE- Allairda_
is measu_d external
_sis_nce.
505342M
05/08