10 Technical Data

10.1 Technical specifications

All dimension an weight specifications refer to a wide range of the wheelchair in a standard configuration. Dimension and weight
(based on ISO 7176–1/4/5/7) may alter according to different configurations. In some configurations, the wheelchair exceed
the recommended dimensions for a wheelchair.
Permissible operating and storage conditions
Temperature range for operation according to ISO 7176-9:
Recommended storage temperature:
Temperature range for storage according to ISO 7176-9:
Relative humidity:
Atmospheric pressure:
Electrical system
Motors
Battery pack
Main fuses
Degree of protection
Charging device
Output current
Output voltage
1640502-B
2 x 150 W
2 x 12 V/12 Ah, leakproof/gel
2 x 12 V/17 Ah, leakproof/gel
3 A and 25 A
IPX4
1
2.5 A
240 V / 24 V
-25° – +50 °C
+15° - +25°C
-25° – +65 °C with battery pack
-40° – +65 °C without battery pack
20% – 75%
800 hPa– 1060 hPa