Other Operations - YASKAWA MP2300 User Manual

Machine controller, basic module
Hide thumbs Also See for MP2300:
Table of Contents

Advertisement

4 System Startup and Sample Programs

4.3.3 Other Operations

4.3.3 Other Operations
This section describes the CPU RUN setting and log-off operation required when MPE720 Ver 5. is used.
( 1 ) CPU RUN Settings
If the CPU STOP status is not cleared after executing processes such as saving to flash memory, use the following
procedure to return to RUN status.
1.
Right-click on the Controller Folder where sample programs are saved and select Controller
Operation from the pop-up menu that is displayed.
The Controller Running Status Dialog Box will appear.
2.
Click the Run Button.
 To stop the CPU, for example to verify errors, click the STOP Button displayed here.
3.
Change confirmation dialog box will be displayed. Click the Yes Button to return to the Controller
Running Status Dialog Box. Check that the RUN LED indicator is lit.
4.
Click the CLOSE Button in the Controller Running Status Dialog Box to exit RUN settings.