The Back Panel - GE Security MCE-Coax User Manual

Table of Contents

Advertisement

The Back Panel

The back panel of the MCE-Coax is shown below.
Figure 3: MCE-Coax back panel
MODE DIP Switch
The MCE-Coax has 4 selective transmission modes. By switching between
the transmission modes, you can obtain the best transmission mode to suit
your phone line quality or distance of connectivity. The following is the
summary table of transmission settings, bandwidth and distance
extensibility without noise and cross talk.
OFF
ON(default)
CO / CPE
CO (Central Office) - the Master device mode, usually the CO device will
be located at the data center of ISP or enterprise to link to the backbone.
CPE (customer premises equipment) - the Slave device mode, usually
the CPE device will be located at a branch office, home or remote side as
MCE-Coax Converter User Manual
DIP-1
DIP-2
Mode
Channel
CO
Interleave
CPE
Fast
Chapter 2: Hardware Overview
DIP-3
DIP-4
Rate Limit
SNR
50/20 Mbps
9dB
No Limit
6dB
9