Functional Description; Extension Cords - Delta 50-767 Instruction Manual

1 1/2 hp dust collector
Table of Contents

Advertisement

3. 240 VOLT SINGLE PHASE OPERATION
The motor supplied with your machine is a dual voltage,
120/240 volt motor. It is shipped ready-to-run for 120
volt operation. However, it can be converted for 240 volt
operation.
A qualified electrician should do the conversion, or the
machine can be taken to an Authorized DELTA
Center. When completed, the machine must conform
to the National Electric Code and all local codes and
ordinances.
The machine is converted by re-wiring the motor for 240
volts, installing a 240 volt plug on the power supply cord
and replacing the switch with one that is rated for 240
volt operation.
Be sure the 240 volt plug is only used in an outlet having
the same configuration as the plug illustrated in Fig. C.
No adapter should be used with the 240 volt plug.
In all cases, make certain that the receptacle
in question is properly grounded. If you are not sure, have a
qualified electrician check the receptacle.

EXTENSION CORDS

Use proper extension cords. Make sure your extension cord is in good condition and is a 3-wire extension
cord which has a 3-prong grounding type plug and matching receptacle which will accept the machine's plug. When using
an extension cord, be sure to use one heavy enough to carry the current of the machine. An undersized cord will cause a
drop in line voltage, resulting in loss of power and overheating. Fig. D-1 or D-2, shows the correct gauge to use depending
on the cord length. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.
MINIMUM GAUGE EXTENSION CORD
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES
Ampere
Total Length of
Volts
Rating
Cord in Feet
0-6
120
up to
0-6
120
25-50
120
50-100
0-6
120
100-150
0-6
6-10
120
up to
25-50
6-10
120
50-100
6-10
120
100-150
6-10
120
10-12
120
up to
10-12
120
25-50
50-100
10-12
120
10-12
120
100-150
12-16
120
up to
25-50
12-16
120
12-16
120
GREATER THAN 50 FEET NOT RECOMMENDED
Fig. D-1
FOREWORD
®
The DELTA
Industrial Model 50-767 Dust Collector will connect to woodworking machines that accept a 4" diameter
hose. The 50-767 comes with one 1 micron filter bag and two 6 mil plastic collection bag.
NOTICE: The photo on the manual cover illustrates the current production model. All other illustrations contained in
the manual are representative only and may not depict the actual labeling or accessories included. These are intended
to illustrate technique only.
®
Service
Gauge of
Extension Cord
25
18 AWG
16 AWG
16 AWG
14 AWG
25
18 AWG
16 AWG
14 AWG
12 AWG
25
16 AWG
16 AWG
14 AWG
12 AWG
25
14 AWG
12 AWG

FUNCTIONAL DESCRIPTION

GROUNDED OUTLET BOX
CURRENT CARRYING
PRONGS
GROUNDING BLADE IS
LONGEST OF 3 BLADES
MINIMUM GAUGE EXTENSION CORD
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES
Ampere
Volts
Rating
0-6
240
0-6
240
240
0-6
240
0-6
6-10
240
6-10
240
6-10
240
6-10
240
10-12
240
10-12
240
10-12
240
10-12
240
12-16
240
12-16
240
12-16
240
6
FIG. C
Total Length of
Gauge of
Cord in Feet
Extension Cord
50
18 AWG
up to
50-100
16 AWG
100-200
16 AWG
200-300
14 AWG
50
18 AWG
up to
50-100
16 AWG
100-200
14 AWG
200-300
12 AWG
50
16 AWG
up to
50-100
16 AWG
100-200
14 AWG
200-300
12 AWG
50
14 AWG
up to
50-100
12 AWG
GREATER THAN 100 FEET NOT RECOMMENDED
Fig. D-2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents