Turbulator Installation - Roberts Gorden VANTAGE NP CTHN-125 Installation & Operation Manual

Negative pressure unitary or multiburner infrared heater
Hide thumbs Also See for VANTAGE NP CTHN-125:
Table of Contents

Advertisement

CTHN-S
I
, O
ERIES
NSTALLATION
PERATION AND
Step 9.9.2 Coupling and Tube Assembly (Continued)
2.3 m
.25 m
Step 9.10 Turbulator Installation
Turbulator section
(stainless) used in
CTHN-40 heaters must be
in the section of tube nearest
to the burner.
Description
Turbulator Adapter
Turbulator Section
Turbulator Section (Stainless)
Tube
38
S
M
ERVICE
ANUAL
3 m
.25 m
Part Number
03051503
03051504
03051505
91409XXX
Model
Tube Length
CTHN-40
10' (4.5 m)
CTHN-60
CTHN-80
CTHN-100
CTHN-125
40' (12 m)
CTHN-150
40' (12 m)
CTHN-175
50' (18 m)
CTHN-200
50' (18 m)
Turbulator must be installed in the last
standard section of radiant tube.
Turbulator is only required on the
CTHN-40, CTHN-60 and CTHN-80.

Turbulator Installation

Model
CTHN-40
CTHN-60
CTHN-80
CTHN-100
CTHN-125
CTHN-150
CTHN-175
CTHN-200
Radiant
20' (6 m)
20' (6 m)
30' (9 m)
Tube Section
1st 10' (3 m) Section
2nd 10' (3 m) Section
2nd 10' (3 m) Section
N/A
N/A
N/A
N/A
N/A