Download Print this page
Omron E2C-EDA11 Instruction Sheet

Omron E2C-EDA11 Instruction Sheet

Proximity sensors with separate digital amplifier amplifier units e2c-eda series

Advertisement

Quick Links

□□
E2C-EDA
Proximity Sensors with Separate Digital Amplifier
Amplifier Units
INSTRUCTION SHEET
TRACEABILITY INFORMATION:
Representative in EU:
Manufacturer:
Omron Europe B.V.
Omron Corporation,
Wegalaan 67-69
Shiokoji Horikawa, Shimogyo-ku,
2132 JD Hoofddorp,
Kyoto 600-8530 JAPAN
The Netherlands
Ayabe Factory
3-2 Narutani, Nakayama-cho,
Ayabe-shi, Kyoto 623-0105 JAPAN
The following notice applies only to products that carry the CE mark:
Notice:
This is a class A product. In residential areas it may cause radio
interference, in which case the user may be required to take adequate
measures to reduce interference.
* 4 0 1 2 1 3 3 - 6 A *
©
OMRON Corporation 2004 All Rights Reserved.
PRECAUTIONS FOR SAFE USE
Please observe the following precautions for safe use of the product.
1) Do not use the Amplifier Unit in environments subject to flammable or explosive gases.
2) Do not use the Amplifier Unit in environments subject to exposure to water, oil, chemicals, etc.
3) Do not attempt to disassemble, repair, or modify the Amplifier Unit in any way.
4) Do not apply voltages or currents that exceed the rated ranges.
5) Wire the Amplifier Unit correctly, e.g., do not reverse the polarity of the power supply.
6) Connect the load correctly.
7) Do not short both ends of the load.
8) Do not use the Amplifier Unit if the case is damaged.
9) When disposing of the Amplifier Unit, treat it as industrial waste.
PRECAUTIONS FOR CORRECT USE
Please observe the following precautions to prevent failure to operate, malfunction, or undesirable
effects on product performance.
1) Wire the Amplifier Unit separately from power supply or high-voltage lines. If the Amplifier Unit
wiring is wired together with or placed in the same duct as high-power lines, inductive noise may
cause operating errors or damage the Amplifier Unit.
2
2) Do not extend the cable to more than 30 m, and use a wire size of 0.3 mm
or larger for the extension cable.
3) The Amplifier Unit is ready to operate 200 ms after the power supply is turned ON. If the Amplifier Unit and load are
connected to power supplies separately, turn ON the power supply to the Amplifier Unit first.
Please turn on the power supply at the same time when you connecting use the Amplifier Units with cables.
Mutual interference prevention might not operate normally or mobile console might not be able to be used
when the difference between connected Amplifiers at the power supply turning or time is 30ms or more.
4) Always keep the protective cover in place when using the Amplifier Unit.
5) When using a connector model, place a protective label (provided with the E3X-CN series connectors) on
the power supply connecting terminals that are not used, to prevent electric shock or short circuit.
6) When using a communication unit connection model, place a protective cap
(provided with the E3X-ECT/CRT communication unit ) on the connecting
terminals that are not used, to prevent electric shock or short circuit.
7) When connecting or removing the communication unit connection
model, make sure that the connecting part is not slanted.
8) Always turn OFF the power supply before connecting or disconnecting Sensor
Heads, joining or separating Amplifier Units, or adding Amplifier Units.
9) If the data is not written to the EEPROM correctly due to a power failure or
static-electric noise, initialize the settings using the keys on the Amplifier Unit.
Power Supply
10) Using a Mobile Console (The communication unit connection
Connecting Terminal
model cannot use a mobile console.)
Use the E3X-MC11-SV2 Mobile Console for the E2C-EDA-series Amplifier Units. Other Mobile
Consoles, such as the E3X-MC11,E3X-MC11-S, cannot be used.
11) Optical communications are not possible with an E3X-DA-N Amplifier Unit.
12) Depending on the application environment, time may be required for the detection level to stabilize after the power supply is turned ON.
13) Output pulses may occur when the power is interrupted and so turn OFF the power to the load or
load line before turning OFF the power to the Sensor.
14) The Sensor Head of E3C-LDA cannot be used. It may damage, if it connects.
15) When mutual interference prevention is confirmed, the execution time of fine positioning becomes long.
16) Do not use thinners, benzine, acetone, or kerosene for cleaning the Amplifier Unit.
17) A disconnection output may be rarely outputted under the large installation conditions of a detection level also except disconnection.
■ Confirming the Package Contents
・ Amplifier Unit: 1     ・ Instruction Sheet (this sheet): 1
1. Ratings and Specifications
Advanced, twin-output models
Advanced, external-input models Communication unit
Type
Connection method
Prewired
Separate
Prewired
Separate
connector
connector
*1
*1
Model
NPN
E2C-EDA11
E2C-EDA6
E2C-EDA21
E2C-EDA7
number
PNP
E2C-EDA41
E2C-EDA8
E2C-EDA51
E2C-EDA9
Supply voltage
12 to 24 VDC±10% ripple(p-p) 10%max.
Power consumption
1,080mW max. (45mA max. at 24 VDC)
Control output
Open collector (26.4 VDC max.);
Load current: 50mA max.; residual voltage: 1 V max.
Timer
OFF, OFF-delay, or one-shot
Timer time
1 ms to 5 s
Differential detection mode
Supported
Fine positioning
Supported
Mutual interference
Supported (intermittent oscillation system)
*2
prevention
response time = (number of Amplifier Units + 1)×15 ms
The number of setting : 2 to 5
I/O settings
Output setting (channel 2 output,
External input setting (teaching
area output, self diagnosis output,
method, fine positioning, zero reset,
or disconnection output)
or synchronous detection)
Response time
Refer to 5.Detailed Settings Detection Method
Groups of 1 to 2 Amplifiers: -10℃to 55℃
Groups of 3 to 5 Amplifiers: -10℃ to 50℃
Operation
Ambient
Groups of 6 to 16 Amplifiers: -10℃ to 45℃ Groups of 17 to 30 Amplifiers: −10°C to 40°C
temperature
Combination with EDR6-□
Groups of 3 to 4 Amplifiers: -10℃ to 50℃
Groups of 5 to 8 Amplifiers: -10℃ to 45℃
Groups of 9 to 16 Amplifiers: -10℃ to 40℃ Groups of 17 to 30 Amplifiers: −10°C to 35°C
−20℃ to 70℃ (with no icing or condensation)
Storage
Ambient humidity
Operation/Storage: 35 to 85 %RH (with no condensation)
Vibration
10 to 55 Hz, 1.5mm double amplitude 2 hours each in X, Y, and Z directions
*1: When using individually or as a master, obtain the E3X-CN21 Master Connector (4-conductor), and when
using as a slave, obtain the E3X-CN22 Slave Connector (2-conductor). Either Connector can be used.
*2: Communications are disabled if SHS is selected for the detection mode, and the communications functions
for mutual interference prevention and the Mobile Console will not function.
*3: Connectable communication units are E3X-ECT (30 units max.) and E3X-CRT (16 units max.). For details
on names of each part and settings, refer to items of the twin output model.
2. Nomenclature
Main display (red)
Twin-output Models : Operation indicator for channel 2
Operation indicator
External-input Models : Fine positioning indicator
UP
SET
Sub-display (green)
SET/RUN switch
Twin-output Models : Channel selector
External-input Models : Operation mode selector
① Lit when the output is ON.
  Twin-output Models: Lit when the output for channel 1 is ON.
② Displays the detection level or the function name.
③ Twin-output Models: Lit when the output for channel 2 is ON.
  External-input Models: Lit when fine positioning is set.
④ Displays supplemental detection information, the setting of a function, etc.
⑤ Used to switch the mode.
⑥ Twin-output Models: Used to select the channel to display or set.
  External-input Models: Used to select normally-open or normally-close operation
⑦ Used to change the display, set functions, etc.
3. Basic Operating Information
Setting the Mode
The mode is set using the SET/RUN switch. Set this switch according to the operation to be performed.
(2/2)
Mode
Description
SET
Select to set detection conditions, to teach the threshold value, to set initializing, etc.
RUN
Select for actual detection operation or set the following: Manual adjustment of
thresholds, Positioning teaching, Teaching with and without a workpiece, Fine
positioning, Zero reset, or Key lock
Key Operations
The operation keys are used to switch the displays and set detection conditions. The functions of the
keys depend on the current mode.
Function
Key
RUN mode
UP key
Increases the threshold.
DOWN key
Decreases the threshold.
MODE key
Depends in the MODE key setting (See note.)
・ Executes positioning teaching(default setting).
・ Teaching with and without a workpiece.
・ Executes fine positioning.
・ Executes a zero reset.
Note: Refer to 4.Basic settings for the setting method.
Protector seal
Reading Displays
Power supply
The information displayed on the main display and sub-display depends on the current mode. For the
connector
default settings, the RUN mode displays will appear when the power supply is turned ON for the first time.
Main display (red)
Mode
Displays the detection level,* function name,
Displays threshold value* or the setting of the
SET
or other information depending on the key
function displayed on the main display depending
operation.
on the key operation.
*The detection level will be displayed even if
*The threshold value for the change in the
Protective Cap
DIFF (differential operation) is set for the
detection level will be displayed if DIFF (differential
detection method.
operation) is set for the detection method.
For the default setting, the current threshold
RUN
For the default setting, the current
value will be displayed.
(See note.)
detection level will be displayed.
The threshold value for the change in the
The change in the detection level will be
detection level will be displayed if DIFF
displayed when DIFF (differential
(differential operation) is set for the detection
operation) is set for the detection mode.
method.
Note: The information that appears on the displays can be set using the display switch
function. Refer to 5. Detailed Settings.
4. Basic Settings
1
Setting the Operation Mode
Select either normally-open or normally-close operation.
Selection
Description
NO(normally-open)
The output will turn ON when the detection level is above the threshold.
(default)
If DIFF (differential operation) is set for the detection method, the output will turn
connection model *3
ON when an edge is detected.
NC(normally-close)
The output will turn ON when the detection level is below the threshold.
E2C-EDA0
If DIFF (differential operation) is set for the detection method, the output will turn
OFF when an edge is detected.
●The setting method depends on the type of Amplifier Unit.
Type
Setting method
Set as the operation mode in SET mode.
Twin-output model
Refer to 5. Detailed Settings.
External-input model
Set using the operation mode selector.
NO
NC
2
Adjusting the sensitivity (as Required)
Fine positioning can be used to adjust the detection level that is currently being received to the fine
Output setting
positioning target value (1,500). Before executes fine positioning, always secure the workpiece and
(2CH output)/area output
Sensor Head and be sure that the detection level is stable.
/self-diagnosis output)
●Setting method
Confirm that the MODE key setting is FP(fine positioning) in advance.
The default is "PPT" (positioning teaching). Refer to 5. Detailed Settings.
Switch to RUN mode.
SET
RUN
Press the MODE key for at
least 3 seconds.
A progress bar will appear
on the sub-display one
Progress bar
FP
digit at a time.(Release the
MODE key when the
progress bar appears.)
Tuning completed and previous display returns.
●Setting Errors
An error has occurred if one of the following display appears the progress bar is displayed.
Flashes twice
Over Error
It is the error for the present workpiece position having been too far to the
fine positioning possible range. It is adjusted by the maximum sensitivity.
DOWN
MODE
FP
OVER
The fine positioning possible range is 50 to 150% of measurement range.
Operation keys
Flashes twice
Bottom Error
RUN
1
2
It is the error for the present workpiece position having been too near to the
fine positioning possible range. It is adjusted by the minimum sensitivity. The
FP
BOTM
fine positioning possible range is 50 to 150% of measurement range.
NO
NC
Flashes twice
Timeout Error
An error occurred because the detection level was not stable during fine
positioning.
FP
TOUT
Make sure that the workpiece and Sensor Head are secured and retune
the sensitivity.
●Clearing method
Switch to RUN mode
SET
RUN
Hold down the MODE key and press the DOWN key for at least 3 seconds.
Note: Press the DOWN key right after pressing the MODE key.
The sub-display will flash twice and fine positioning will be cleared.
FP
OFF
3
Setting Thresholds
① Positioning Teaching
Teaching is performed in the state where a workpiece is in an ON
point. A detection level is set up as a threshold value.
Teaching cannot be performed when DIFF(differential operation) is set as the detection
method.
●Setting method
SET mode
In the case of a 【Method 2】 , please check that a setup of a "MODE key setting" function is
Depends on the setting.
・ Executes teaching.
[PPT](positioning teaching) in advance. Refer to 5.Detailed Settings.
・ Changes the setting forward.
Method 1
Depends on the setting.
・ Executes teaching.
Switch to SET
・ Changes the setting in reverse.
mode.
SET
RUN
Switches the function to be set on the
Press the UP or DOWN
display.
key for at least 3 seconds.
The threshold
value that was set
PPT
Threshold
will flash twice.
value
Teaching completed and
Sub-display (green)
previous display returns.
② Teaching With and Without a Workpiece
Teaching can be performed twice, once with and once without a workpiece, and the value between
the two measured values is set as the threshold.
If DIFF (differential operation) is set for the detection method, the threshold value
will be set to half of the difference between the two measured values.
●Setting method
In the case of a 【Method 2】, please check that a setup of a "MODE key setting" function is
[2PNT](teaching with and without a workpiece) in advance. Refer to 5.Detailed Settings.
【Method 1】
Switch to SET
mode.
SET
RUN
Position a workpiece
and press the
UP or DOWN key.
Workpiece
The sub-display
will flash.
----
TECH
A detection margin
level can check the
margin of the present
Display alternates
at a fixed interval.
detection level to the
variation in a detection
level with a workpiece.
Detection
Detection
level
margin value
Remove the
workpipece and
press the UP or
DOWN key.
The threshold
Main Display
value that was set
will flash twice.
2PNT
Threshold
value
FP
Display alternates
During fine
Teaching completed and
at a fixed interval.
positioning
previous display returns.
Fine positioning target value
●Setting Errors
An error has occurred if any of the following is display when the UP or DOWN key is pressed
without a workpiece.
Flashes twice
2PNT
OVER
Flashes twice
2PNT
③ No-workpiece Teaching
Teaching is performed in the state where there is no workpiece.
It sets up about +6% of a detection level as a threshold value. It is stabilized and a very small
difference can be detected.
If DIFF(differential operation) is set for the detection method, the threshold value will be set
to the minimum value above the detection level without a workpiece that will enable stable
detection.
Sensor head
Without a workpiece
●Setting method
Sensor head
SET
RUN
Press the UP or DOWN key.
ON point
TECH
Press the UP or DOWN key for at least 3 seconds.
A detection level and a detection margin value are displayed.
Method 2
Switch to RUN
mode.
SET
RUN
Threshold
NEAR
value
Press the MODE key for
●Setting Errors
at least 3 seconds.
The threshold
value that was set
PPT
Threshold
will flash twice.
Teaching completed and previous display returns.
value
4
Teaching completed and
Manually Setting Threshold Values
previous display returns.
A threshold value can be set manually.
●Setting method
SET
RUN
Detection
Threshold
level
value
Adjust the threshold value with the UP and DOWN keys.
【Method 2】
Switch to RUN
mode
SET
RUN
When the UP or DOWN key is pressed to change the threshold value, the threshold
value will be displayed on the sub-display regardless of the display switch setting.
The information set for the display switch setting will return approximately 5 seconds
Position a workpiece
after the threshold is changed.
and press the MODE
key for at least 3
5
seconds.
A zero point is registered. (zero reset)
Workpiece
The standard position of a workpiece is registered as "detection level =0", and it judges to the amount of
change of a detection level. When there is change of the standard position of a workpiece or change of
the detection level by the operating condition, detection stabilized when performing zero reset can be
The sub-display will
performed.
flash.
Execution of zero reset shifts to "0" the detection level currently displayed on the main display. The
TECH
----
threshold value currently displayed on the sub display is not shifted.
Please set "a MODE key settings" as "0RST" in advance. The default is "PPT" (positioning teaching).
Refer to 5.Detailed Settings.
A detection margin
level can check the
margin of the present
Display alternates
Zero reset cannot be performed when DIFF(differential operation) is set as the
at a fixed interval.
detection level to the
detection method.
variation in a detection
level with a workpiece.
Workpiece
Detection
Detection
margin value
level
Remove the
workpiece and
Zero reset execution
press the MODE
●Setting method
key for at least 3
seconds.
Switch to RUN mode.
The threshold
SET
RUN
value that was set
Press the MODE key for at
will flash twice.
2PNT
Threshold
least 3 seconds.
value
The display of a detection
level is fixed.
Teaching completed and
previous display returns.
Detection
Threshold
level
value
Do one of the following and then repeat the operation
・ Adjust the Head to decrease the detection level.
・ Execute fine positioning.
Do one of the following and then repeat the operation
・ Adjust the Head to increase the detection level.
・ Execute fine positioning.
LO
Switch to SET mode.
The sub-display will flash.
----
The threshold value that was set will flash twice.
Flashes twice
Do one of the following and then repeat the operation
・ Adjust the Head to decrease the detection level.
・ Execute fine positioning.
NEAR
OVER
Switch to RUN mode.
The information set for the display switch will be displayed.
(The default setting is for the detection level and the threshold value.)
Increases the threshold value.
Decreases the threshold value.
Next workpiece
This level difference
is judged.
This level difference
is judged.
Zero reset execution
●Clearing method
Switch to RUN mode.
SET
RUN
The DOWN key is pushed 3
seconds or more, pushing
the MODE key. Press the
DOWN key right after
pressing the MODE key.
Zero reset is
Zero reset is
performed and a
detection level is
cleared.
Detection
Threshold
shifted to "0."
level
value

Advertisement

loading

Summary of Contents for Omron E2C-EDA11

  • Page 1 Setting the Mode * 4 0 1 2 1 3 3 - 6 A * © OMRON Corporation 2004 All Rights Reserved. The mode is set using the SET/RUN switch. Set this switch according to the operation to be performed. (2/2) Without a workpiece The sub-display will flash twice and fine positioning will be cleared.
  • Page 2 Detection level PEAK detection level. ●Removing Units OMRON shall not be responsible for conformity with any standards, codes, or Setting range: 1 to 5,000 Display alternates Timer Time at a fixed interval. regulations that apply to the combination of the products in the customer's Press the Unit in the direction indicated by "1"...

This manual is also suitable for:

E2c-eda8E2c-eda6E2c-eda41E2c-eda21E2c-eda51E2c-eda7 ... Show all