UK FLUE REQUIREMENTS - POSITIONING
Dimension Terminal Position
A
Directly below an opening, air brick, opening windows, etc.
B
Above an opening, air brick , opening window, etc.
C
Horizontally to an opening, air brick , opening window, etc.
D
Below gutters, soil pipes or drain pipes.
E
Below eaves.
F
Below balconies or car port roof.
G
From a vertical drain pipe or soil pipe.
H
From an internal or external corner.
I
Above ground, roof or balcony level.
J
From a surface facing the terminal.
K
From a terminal facing a terminal
L
From an opening in a car port. ( eg door, window) into a dwelling
M
Vertically from a terminal on the same wall.
N
Horizontally from a terminal on the same wall.
O
From the wall on which the terminal is mounted
P
From a vertical structure on the roof.
Q
Above an intersection with roof.
33
Distance
300mm
300mm
300mm
75mm
200mm
200mm
150mm
200mm
300mm
600mm
1200mm
1200mm
1500mm
300mm
N/A
N/A
N/A