Clearances From Appliance; Attachment Of The Water Heater - Rinnai R63LSe Operation And Installation Manual

Outdoor tankless water heater
Hide thumbs Also See for R63LSe:
Table of Contents

Advertisement

Clearances from Appliance

to
Combustibles
Top of
12 inches
Heater
(305 mm)
Back of
0 (zero)
Heater
Front of
24 inches
Heater
(610mm)
Sides of
6 inches
Heater
(152 mm)
Floor/
12 inches
Ground
(305 mm)
The clearance for servicing is 24 inches in front of the water heater

Attachment of the Water Heater

1. Identify the installation location and confirm that
the installation will meet all required clearances.
2. Securely attach the water heater to the wall using
any of the holes in the wall installation brackets
which are at the top and bottom of the water
heater. Ensure that the attachment strength is
sufficient to support the weight. Refer to the
weight of the water heater in the Specifications
section.
18
to Non-
Combustibles
2 inches
(51 mm)
0 (zero)
24 inches
(610 mm)
1/2 inch
(13 mm)
2 inches
(51 mm)
VA Series Outdoor LS Manual
to top
to side
to floor/ground
to front
wall installation
brackets