Environment

Air surrounding the water heater, venting, and vent termination
(s) is used for combustion and must be free of any compounds
that cause corrosion of internal components. These include
corrosive compounds that are found in aerosol sprays, deter-
gents, bleaches, cleaning solvents, oil based paints/ varnish-
es, and refrigerants. The air in beauty shops, dry cleaning
stores, photo processing labs, and storage areas for pool sup-
plies often contains these compounds. Therefore Rinnai rec-
ommends that outdoor models be used for these locations
where possible.
The water heater, venting, and vent termination(s) should not
be installed in any areas where the air may contain these cor-
rosive compounds. If it is necessary for a water heater to be
located in areas which may contain corrosive compounds, the
following instructions are strongly recommended.
IMPORTANT CONSIDERATIONS FOR:
Indoor/Internal Water Heaters
DO NOT Install in areas where air for combustion can be
contaminated with chemicals.

Clearances from Appliance

RV53i
to Com-
bustibles
Top of
6 inches *
Heater
(152 mm)
Back of
0 (zero)
Heater
Front of
6 inches
Heater
(152 mm)
Sides of
2 inches
Heater
(51 mm)
Ground/
12 inches
Bottom
(305 mm)
Vent
0 (zero)
* 0 inches from vent components and condensate drain line.
The clearance for servicing is 24 inches in front of the water heater.
For V53i closet installation: clearance is 6 inches (152 mm) from the front.

Attachment of the Water Heater

1. Identify the installation location and confirm that the
installation will meet all required clearances.
2. Securely attach the water heater to the wall using any of the
holes in the wall installation brackets which are at the top
and bottom of the water heater. Ensure that the attachment
strength is sufficient to support the weight. Refer to the
weight of the water heater in the Specifications section.
NOTE: Rinnai water heaters should be installed in an upright
position. Do not install upside down or on it side.
to Non-
RV53e
Com-
bustibles
2 inches *
Top of
(51 mm)
Heater
Back of
0 (zero)
Heater
6 inches
Front (Panel)
(152 mm)
1/2 inch (13
Front
mm)
(Exhaust)
12 inches
Sides of
(305 mm)
Heater
0 (zero)
Floor/Ground
RV53i & RV53e Operation and Installation Manual
Before installation, consider where air has the ability to
travel within the building to the water heater.
Where possible, install the water heater in a sealed clos-
et so that it is protected from the potential of contaminat-
ed indoor air.
Chemicals that are corrosive in nature should not be
stored or used near the water heater.
Outdoor/External Water Heaters and Vent Terminations of
Indoor/Internal Water Heaters
Install the water heater as far away as possible from
exhaust vent hoods.
Install as far away as possible from air inlet vents. Cor-
rosive fumes may be released through these vents when
air is not being brought in through them.
Chemicals that are corrosive in nature should not be
stored or used near the water heater or vent termination.
Damage and repair due to corrosive compounds in the air is
not covered by warranty.
to Non-
to Com-
Com-
bustibles
bustibles
12 inches
2 inches
(305 mm)
(51 mm)
0 (zero)
0 (zero)
24 inches
0 (zero)
(610 mm)
24 inches
24 inches
(610 mm)
(610 mm)
6 inches
1/8 inch
(152 mm)
(3.2 mm)
12 inches
2 inches
(305 mm)
(51 mm)
wall installation
brackets
15