Error Code Table - Rinnai R63LSe Operation And Installation Manual

Outdoor tankless water heater
Hide thumbs Also See for R63LSe:
Table of Contents

Advertisement

Error Code Table

Error
Fault
14
Thermal Fuse
16
Over Temperature
Warning
32
Outgoing Water
Temperature Sensor
Fault
33
Heat Exchanger
Outgoing Temperature
Sensor Fault
34
Combustion Air
Temperature Sensor
Fault
52
Modulating Solenoid
Valve Signal Abnormal
61
Combustion Fan
Failure
65
Water Flow
Servo
Faulty
(does not stop flow properly)
71
SV0, SV1, SV2, and
SV3 Solenoid Valve
Circuit Fault
72
Flame Sensing Device
Fault
LC
Scale Build-up in Heat
Exchanger (when
checking maintenance
code history "00" is
substituted for "LC")
No
Nothing happens when
code
water flow is activated.
14
Remedy
Check gas type of unit and ensure it matches gas type being used.
Check for restrictions in air flow around unit and vent terminal.
Check for low water flow in a circulating system causing short-cycling.
Ensure dip switches are set to the proper position.
Check for foreign materials in combustion chamber and/or exhaust piping.
Check heat exchanger for cracks and/or separations.
Check heat exchanger surface for hot spots which indicate blockage due to scale build
up. Refer to instructions in manual for flushing heat exchanger.
Measure resistance of safety circuit.
Ensure high fire and low fire manifold pressure is correct.
Check for improper conversion of product.
Check for restrictions in air flow around unit and vent terminal.
Check for low water flow in a circulating system causing short-cycling.
Check for foreign materials in combustion chamber and/or exhaust piping.
Check for clogged heat exchanger.
Check sensor wiring for damage.
Measure resistance of sensor.
Clean sensor of scale build up.
Replace sensor.
Check sensor wiring for damage.
Measure resistance of sensor.
Clean sensor of scale build up.
Replace sensor.
Check for restrictions in air flow around unit and vent terminal.
Check sensor wiring for damage.
Measure resistance of sensor.
Clean sensor of scale build up.
Ensure fan blade is tight on motor shaft and is in good condition.
Replace sensor.
Check modulating gas solenoid valve wiring harness for loose or damage terminals.
Measure resistance of valve coil.
Ensure fan will turn freely.
Check wiring harness to motor for damaged and/or loose connections.
Measure resistance of motor winding.
If blank screen is present on remote control then the flow control has shorted out.
Unplug flow control. If remote lights up and unit starts operating then replace flow
control assembly.
Check wiring harness to all solenoids for damage and/or loose connections.
Measure resistance of each solenoid valve coil.
Ensure flame rod is touching flame when unit fires.
Check all wiring to flame rod for damage.
Remove flame rod and check for carbon build-up; clean with sand paper.
Check inside burner chamber for any foreign material blocking flame at flame rod.
Measure micro amp output of sensor circuit with flame present.
Replace flame rod.
Flush heat exchanger. Refer to instructions in manual.
Replace heat exchanger.
Clean inlet water supply filter.
On new installations ensure hot and cold water lines are not reversed.
Check for bleed over. Isolate unit from building by turning off hot water line to building.
Isolate the circulating system if present. Open your pressure relief valve; if unit
fires, there is bleed over in your plumbing.
Ensure you have at least the minimum flow rate required to fire unit.
Ensure turbine spins freely.
Measure the resistance of the water flow control sensor.
Check for DC shorts at components
VA Series Outdoor LS Manual