Correct Setting:
The distance between the tip of needle on the right and the surface of needle plate should be 11.6
to 12.2 mm when the needle bar is at the highest position.
To adjust:
1. Remove the face plate unit.
2. Turn the handwheel toward you with your hand, and set the needle bar at its highest position.
3. Loosen the setscrew A to adjust the height, and tighten the setscrew A after the adjustment is
done.
4. Turn the handwheel toward you one complete turn, and recheck the needle bar height.
5. Attach the face plate unit.