Troubleshooting

WARNING:
!
For your own safety do not try
and run the air compressor
while troubleshooting.
TROUBLE
Compressor will not
run
Motor hums but can-
not run or runs slow-
ly
Fuses blow/circuit
breaker trips repeat-
edly
PROBABLE CAUSE
1. Unit is plugged into
extension cord
2. No electrical power
3. Blown fuse
4. Breaker open
5. Thermal overload open
6. Pressure switch bad
1. Low voltage
2. Unit is plugged into
extension cord
3. Shorted or open motor
winding
4. Defective check valve or
unloader
1. Incorrect size fuse, circuit
overloaded
2. Unit is plugged into
extension cord
3. Defective check valve or
unloader
16
REMEDY
1. Remove extension cord
2. Plugged in? Check
fuse/breaker or motor
overload
3. Replace blown fuse
4. Reset, determining why
problem happened
5. Motor will restart when
cool
6. Replace
1. Check with voltmeter
2. Remove extension cord
3. Replace motor
4. Replace or repair
1. Check for proper fuse, use
time-delay fuse.
Disconnect other electrical
appliances from circuit or
operate compressor on its
own branch circuit
2. Remove extension cord
3. Replace or repair