8. After all maintenance is complete, refer to the Trim Replacement procedure to assemble the valve body.
Note
If the valve has ENVIRO‐SEAL™ live‐loaded packing installed, see the Fisher instruction manual titled ENVIRO‐SEAL Packing System
for Sliding‐Stem Valves (D101642X012) for packing instructions.
If the valve has HIGH‐SEAL live‐loaded packing installed, see the Fisher instruction manual titled HIGH‐SEAL Live‐Loaded Packing
System (D101453X012) for instructions.
Figure 2. Lubricator and Lubricator/Isolating Valve
10A9421‐A
AJ5428‐D
LUBRICATOR/ISOLATING VALVE
A0832‐2

Packing Lubrication

WARNING
To avoid personal injury or property damage resulting from fire or explosion, do not lubricate packing used in oxygen
service or in processes with temperatures over 260_C (500_F).
CAUTION
Do not lubricate graphite packing. Graphite packing is self-lubricated. Additional lubrication may result in slip-stick
movement of the valve.
Note
ENVIRO‐SEAL or HIGH‐SEAL packing does not require lubrication.
6
14
LUBRICATOR
14
27