Packing Lubrication - Fisher EUT-2 Instruction Manual

Eu series; ew series nps 12 through 24 x 20
Table of Contents

Advertisement

Instruction Manual
August 2010
B2398/IL

Packing Lubrication

If a lubricator or lubricator/isolating valve (figure 3) is
provided for PTFE/composition or other packings
that require lubrication, it will be installed in place of
the 1/4 NPT pipe plug (key 14, figure 5). Use a
EU and EW Series Valves
Figure 4. Typical Packing
silicon-base lubricant. To operate the lubricator, turn
the cap screw clockwise to force the lubricant into
the packing box. The lubricator/isolating valve
operates the same way except the isolating valve
must first be opened and then closed after
lubrication is completed.
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

EudEutEwt-2EwdEwt

Table of Contents