After the error has been eliminated, all error messages must be acknowledged by pressing START on the interior display
No.
Status message
01
Excess temperature bimetal
02
Maximum tanning time!
Excess temperature exhaust
03
fan!
KBL7 Hardware error Input-
12
Controller
Maximum write cycle flash
13
memory reached
Error! SD card read error
14
(CRC fault)
Error! no access to the SD
15
card
Parameter
17
found, please connect and
restart
Parameter storage no valid
18
serial number
CAN-BUS: Interior display
19
V1 is incompatible
CAN-BUS: preSelection dis-
20
play V1 is incompatible
CAN-BUS: audio module full
21
V1 is incompatible
CAN-BUS: RGB module V1
22
ist incompatible
Parameter storage write er-
23
ror
24
Parameter storage read error
Frequency detection: detec-
25
tion failed!
Frequency detection: power
26
supply
connection
(connector X6/E6)!
42
O p e r a t i n g I n s t r u c t i o n s | megaSun space 2000
Description
Bimetal switch triggers.
Enabling signal from coin-box system
comes in longer than the time value
approved under "Maximum tanning time"
(voltage remains connected)
Bimetal switch in the fan triggers.
Mainboard defective.
Maximum write cycle flash memory
reached.
Update via SD card failed (CRC fault).
Update via SD card failed (access error).
storage
not
Parameter storage not found, please con-
nect and restart.
Parameter storage no valid serial number.
CAN-BUS operators incompatible.
Parameter storage write error.
Parameter storage read error.
Frequency detection failed.
Frequency detection failed. No mains volt-
faulty
age.
ERROR MESSAGES
Remedy
Check the air-intake/air-discharge system. Let the
device cool down.
Disconnect from the coin-box system.
Make sure the fan runs freely. Check the air-intake/air-
discharge system. Let the device cool down.
Contact your Customer Service.
Contact your Customer Service.
SD card check / replace.
SD card check / replace
Check connector parameter storage. If necessary re-
place parameter storage.
Contact your Customer Service.
Use CAN-BUS operaters V2.
Check connector parameter storage. If necessary re-
place parameter storage.
Check connector parameter storage. If necessary re-
place parameter storage.
Restart the controller. Contact your Customer Service
after the third unsuccessful restart.
Check mainboard connector X6/E6.
.