Unitary Diagnostic Codes - Goodman ComfortNet ASXC160**1AA Series Service Instructions Manual

Asxc, dsxc, and gsxc condensing units, aszc, dszc and gszc split system heat pumps with r-410a refrigerant blowers, coils, & accessories
Table of Contents

Advertisement

SERVICING
Air conditioner/heat pump
fails to operate.
Integrated control
module diagnostic/status
LED display shows the
indicated code.
displays error message.
Air conditioner/heat pump
fails to operate.
Integrated control
module diagnostic/status
LED display shows the
indicated code.
displays error message.
Air conditioner/heat pump
fails to operate.
Air conditioner/heat pump
operating at reduced
performance.
Air conditioner/heat pump
operating at low stage
when expected to operate
at high stage.
Integrated control
module diagnostic/status
LED display shows the
indicated code.
displays error message.
58
d
0
Data not yet
d
1
Invalid Data
d
2
System
Mis-Match
SYSTEM
d0
Air conditioner/
DATA
heat pump is
wired as part of
a communicating
system and
integrated control
module does
not contain any
shared data.
d1
Air conditioner/
DATA
heat pump is
wired as part of
a communicating
system and
integrated control
module contains
invalid shared
data or network
data is invalid for
the integrated
control module.
d2
Air conditioner/
heat pump is
wired as part of
a communicating
system and
outdoor unit
requires airflow
greater than
indoor unit's
airflow capability.
Shared data is
incompatible
with the system
or missing
parameters.
PCBHR104
Verify
Turn power OFF prior
system type
to repair.
(communicating
Use memory card for
or legacy)
your specific model.
Populate shared
Insert memory card
data using
BEFORE turning power
memory card
Wire system as
be removed after data
legacy system
is loaded. Turn power
OFF before removing
memory card.
Error code will
be cleared once
data is loaded.
Applies only to fully
communicating system
thermostat.
Verify
Turn power OFF prior
system type
to repair.
(communicating
Use memory card for
or legacy).
your specific model.
Populate correct
Insert memory card
shared data using
BEFORE turning power
memory card.
Wire system as
be removed after data
legacy system.
is loaded. Turn power
OFF before removing
memory card.
Error code will
be cleared once
data is loaded.
Applies only to fully
communicating system
thermostat.
Verify system type
Turn power OFF prior
(communicating
to repair.
or legacy).
Use memory card for
Verify shared
your specific model.
data is correct
Insert memory card
for your specific
BEFORE turning power
model; re-
populate data if
be removed after data
required.
is loaded. Turn power
Wire system as
OFF before removing
legacy system.
memory card.
Error code will
be cleared once
data is loaded.
Applies only to fully
communicating system
thermostat.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comfortnet asxc160481baComfortnet asxc160601baComfortnet asxc160241bbComfortnet asxc160361bbComfortnet asxc160481bbComfortnet asxc160601bb ... Show all

Table of Contents