Mbvc - Goodman ComfortNet ASXC160**1AA Series Service Instructions Manual

Asxc, dsxc, and gsxc condensing units, aszc, dszc and gszc split system heat pumps with r-410a refrigerant blowers, coils, & accessories
Table of Contents

Advertisement

ACCESSORIES WIRING DIAGRAMS

MBVC

PL1
PL2
RD
2
2
RD
3
3
BK
1
1
6
6
WH
BR
5
5
BL
4
4
7
7
8
8
9
9
4 CIRC UIT HEA TER
SEE
NOTE 7
BK
SEE NOTE 6
RD
4
3
2
BL
1
GY
BK
RD
ECM MOTOR
HARNESS
NOTES:
1. PLACE RED WIRES ON TRANSFORMER TERMIN AL 2 FOR 208 VAC OPER ATION.
2. MANUFACTURER'S
SPECIFIED RE PLACE MENT PA RTS MU ST BE U SED WHEN SERVICING.
3. IF ANY OF THE ORIGINAL WIRES
AS SU PPL IED WITH THIS UNIT MU ST BE R EPLACED,
IT MU ST BE R EPLACED WITH WIR ING M ATERI AL HAVING A TE MPER ATURE R ATING OF AT
LEAST 105°C. USE CO PPER CON DUCTORS O NLY.
4. UNIT MUST BE PER MANE NTLY GROUNDED AN D CONF ORM TO N.E.C A ND LOC AL CODES.
5. TO RECA LL THE LAST 6 FA ULTS, M OST RECENT TO LEA ST RECENT, D EPRE SS
SWITCH FOR MORE T HAN 2 SECONDS WHILE IN
6. RED STATUS LED PROVIDES N ETWORK STATUS. GREEN RX LED IND ICATE S NETWORK TRAFFIC.
USE LEARN B UTTON TO RES ET N ETWORK.
7. DISCARD C ONNECTOR PL1 WHEN INS TALLING O PTIONAL H EAT KI T.
8. THE CONDENS ATE ALARM SW ITCH (CA S) TERMIN ALS CAN ONLY BE UTILIZED W ITH CO MMUN ICATING
MODE S ETUPS AND MU ST BE ENA BLED WITH A COMMUNIC ATING THERM OSTAT. THIS F EATURE IS N OT
OPER ATIONAL W ITH LEGACY SY STE MS.
USE N.E.C CLA SS 2 WIRE.
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
108
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
40 VA TRANS FORMER, SEE N OTE 1
230 VAC
RD
3
208 VAC
24 VAC
2
COM
1
BL
BK
C
W2 W1
CONN ECT OR
24 V 3 A
LEARN
SEE NOTE 5
FAULT
SEE NOTE 6
RECALL
STATUS
LED
7 SEGMENT
DIAGNOSTIC
DISPLAY
CFM LED
SEE NOTE 6
RX LED
S1 S2 S3 S4
S5 S6 S7 S8
S9 S10 S11 S12 S13
DIP SWITCHES
TWO-STAGE INTEGRATED CONTROL MODULE
CIRCULATOR BLOWER
4 3 2 1
1
2
3
4
5
BK
STANDBY (NO THERM OSTAT INPU TS)
GRND
GN
DISCONNECT
BL
RD
TR
TH
COM
FUSE
CAS
SEE NOTE 8
L1
DEHUM
FUSE 3 A
O
R
Y2
Y1
W1
W2
W1
W2
G
Y1
C
R
TO
Y2
MICRO
2
1
G
O
DEHUM
C
GN
GRND
RD
INTEGRATED CONTROL
LOW VOLTAGE (24V)
LOW VOLTAGE FIE LD
HI VOL TAGE (230V)
HI VOL TAGE FIE LD
JUNCTI ON
TERMINAL
INTE RNAL TO
EQ UIPMENT GRND
FIEL D GRND
FIELD SPL ICE
RE SISTOR
OVERCUR RENT
PROT. DEV ICE
PLUG CONNECTION
L1
L2
GRND
INDOOR
AIR
CIRCU LATOR
BLWR
GRND
208/230 VAC
40 VA
TRANSFORMER
TH
24 VAC
W1 (1)
HEAT 1 COIL/R1
W2 (2)
HEAT 2 COIL/ R2
CAS (1)
CONDENSATE SWITCH
CAS (2)
+VDC (1)
RX (2)
IND OOR
AIR
TX (3)
CIRC ULAT OR
BLW R
GRND (4)
TR
COM
INTEGRATED CONTROL MODULE
COLOR CODES:
PK ---- PINK
BR ---- BROWN
WH ---- WHITE
BL ---- BLUE
GY ---- GRAY
RD ---- RED
YL ---- YELLOW
OR ---- ORANGE
PU ---- PURPLE
GN ---- GREEN
BK ---- BLACK
L2
GRND
0140A00244-B