Recovery in U.S. Gallons/Hr. (GPH) and Liters/Hr. (LPH) at Various Temperature Rises
MODEL
INPUT (BTU/HR)
THERMAL
NUMBER
NAT. & LP
EFFICIENCY
HE45-100
100,000
95%
HE45-130
HE80-130
130,000
95%
HE119-130
HE80-160
160,000
95%
HE119-160
HE80-199
199,000
95%
HE119-199
Recovery rating is based on thermal efficiencies obtained in an AGA certified laboratory.
BOOSTER MODELS
MODEL
INPUT (BTU/HR)
THERMAL
NUMBER
NAT. & LP
EFFICIENCY
HE45-160
160,000
95%
HE45-199
199,000
95%
All models exceed the minimum NAECA energy efficiency requirements of ASHRAE 90.1b-1989, 1992 requirements.
MAXIMUM DELIVERY
In U.S. Gallons and Liters (Includes useable storage and recovery for indicated times)
MODEL
GALLONS/
MAX.
INPUT (BTU/HR)
NUMBER
LITERS
SETPOINT
NAT. & LP
45
HE45-100
160º
170
45
HE45-130
160º
170
80
HE80-130
160º
303
119
HE119-130
160º
450
45
HE45-160
180º*
170
80
HE80-160
160º
303
119
HE119-160
160º
450
45
HE45-199
180º*
170
80
HE80-199
160º
303
119
HE119-199
160º
450
All models have a maximum setpoint of 160°F with the exception of the HE45-160 and HE45-199 booster models. The HE45-160 and HE45-199 have a maximum setpoint of 180°F.
* NOTE: The 180º F models are shipped with all necessary components for an approved installation (see Booster Installation Kit for component list.)
DIMENSIONAL INFORMATION
All dimensions shown in English and Metric
MODEL
NUMBER
UNITS
HEIGHT
inches
42
HE45-100
HE45-130
mm
1067
inches
42
HE45-160
HE45-199
mm
1067
HE80-130
inches
72
HE80-160
mm
1854
HE80-199
HE119-130
inches
73
HE119-160
mm
1854
HE119-199
All models require a 120V power source.
* 130,000 Btu models are certified to be installed with 2" venting.