3.2 Specification

Gas boiler, type B and C, category II
Type
Rated heating output range (details to EN 677)
T
/T
= 50/30 °C
F
R
T
/T
= 80/60 °C
F
R
Rated heating output for DHW heating
Rated heat input
Product ID
IP rating
Gas supply pressure
Natural gas
LPG
Max. permissible gas supply pressure
Natural gas
LPG
Sound power level
(to EN ISO 15036-1)
At partial load
At rated heating output (DHW heating)
Power consumption
(in the delivered condition)
Weight
Heat exchanger capacity
Max. flow temperature
Max. flow rate
(Limit for the use of hydraulic separation)
Nominal circulating water volume
At T
/T
= 80/60 °C
F
R
Diaphragm expansion vessel
Capacity
Pre-charge pressure
Permiss. operating pressure
Safety valve connection
Dimensions
Length
Width
Height
Gas connection
Connection values
relative to max. load
With gas
Natural gas E
Natural gas LL
LPG P
*9
If the gas supply pressure is higher than the maximum permissible value, install a separate gas pressure governor upstream of the sys-
tem.
VITODENS
2N3P
kW
kW
kW
kW
mbar
kPa
mbar
kPa
*9
mbar
kPa
mbar
kPa
dB(A)
dB(A)
W
kg
l
°C
l/h
l/h
l
bar
kPa
bar
MPa
Rp
mm
mm
mm
R
m
3
/h
m
3
/h
kg/h
B3HB
1.9 - 11.0
1.9 - 19.0
1.7 - 10.1
1.7 - 17.2
1.7 - 16.0
1.7 - 17.2
1.8 - 16.7
1.8 - 17.9
CE-0085CM0463
IP X4 to EN 60529
20
20
2
2
50
50
5
5
25.0
25.0
2.5
2.5
57.5
57.5
5.75
5.75
29
29
41
48
36
49
50
50
3.8
3.8
74
74
1000
1200
434
739
10
10
0.75
0.75
75
75
3
3
0.3
0.3
¾
¾
360
360
450
450
850
850
½
½
1.77
1.89
2.05
2.20
1.31
1.40
4.0 - 26.0
4.0 - 35.0
3.6 - 23.7
3.6 - 31.7
3.6 - 23.7
3.6 - 31.7
3.8 - 24.7
3.8 - 33.3
20
20
2
2
50
50
5
5
25.0
25.0
2.5
2.5
57.5
57.5
5.75
5.75
33
33
48
51
63
83
48
50
5.6
5.6
74
74
1400
1600
1018
1376
3
3
0.3
0.3
¾
¾
380
380
480
480
850
850
½
½
2.61
3.52
3.04
4.10
1.93
2.60
VIESMANN