LOCATING YOUR
GAS FIREPLACE
1) When selecting a location for your fi replace,
ensure that the clearances are met as
outlined in the "Clearances" section.
2) Provide adequate clearances for servicing.
3) The appliance must be installed on a fl at,
solid, continuous surface (e.g. wood, metal,
concrete). This may be the fl oor, or raised up
on a platform to enhance its visual impact.
If the appliance is going to be installed
on carpeting, combustible linoleum tile or
other combustible material other than wood
fl ooring, the appliance must be installed on a
metal or wood panel extending the full width
and depth of the appliance.
4) The Direct Vent Gas Fireplace can be
installed as follows:
Model #
Position
A)
P121-2:
See Thru
B)
P131-2:
Pier
C)
P121LC-2:
Left Corner
D)
P121RC-2:
Right Corner
5) This appliance is Listed for bedroom
installations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
6) The P121-2/P121LC-2/P121RC-2/P131-
2 Direct Vent Gas Fireplace is approved
for alcove installations, which meet the
clearances listed on this page.
7) We recommend that you plan your installation
on paper using exact measurements for
clearances and floor protection before
actually installing this appliance. Have a
qualifi ed inspector, dealer, or installer review
your plans before installation.
Note: For Exterior Vent Termination
Locations see section "Exterior Vent
Termination Locations."
®
Regency
P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct Vent Gas Fireplace
A) P121-2 See Thru
B) P131-2 Pier
C) P121LC-2 Left Corner
D) P121RC-2 Right Corner
INSTALLATION