COLLECTOR INSTALLATION

FASTENING COLLECTORS TO A TILED ROOF

This type of installation is not suitable for use on roofs over 10 m high.
This type of installation is not suitable for use in cyclonic areas.
WARNING
Attach the collector mounting straps to the rafter or
truss under the tiles.
Place the collector(s) onto the roof above the lower
rail. If more than one collector is being installed then
join them together using the barrel unions supplied.
Using the supplied self drilling screws, fasten the rail
to the collector, through the square holes in the rail
as shown in the relevant diagram on page 12 to
19. Do not fasten in other locations as damage
to the collector header pipe may occur. Be careful
to adequately tighten the screws to ensure the
connection is secure without stripping the threads in
the collector case.
Position the upper collector rail above the collectors.
Fasten the rail to the collector, through the square
holes in the rail using the supplied self drilling screws.
Attach the collector mounting straps to the rafter or
truss under the tiles.
Replace the tiles and ensure the collector is secure,
and the roof is weather tight.
Rinnai
Tiles removed
Nail strap to rafter
Tiles removed
Nail strap
to rafter