Technical Data

Pressure washer
Article number
Rated power
Supply Temperature max.
Supply rate min.
Rated pressure
Max. operating pressure
Flow rate
Maximum inlet pressure
Kickback force at the gun to the maximum pressure
Motor Insulation
Motor Protection
Detergent tank
Autostop function
Net impedance
Sound pressure level
Uncertainty
Sound power level
Uncertainty
Vibration total value
Uncertainty
Weight according to EPTA-Procedure 01:2014
Protection class
Serial number
Mounting and Operation
Action
Delivery Scope
Handle Assembly
Filling up detergent tank
Water connection
Cleaning the Filter
Connecting high pressure water supply hose/
nozzle
Adjust water pressure
Adjust water jet
Switching On and Off
Clean nozzle
Starting
For Your Safety
Warning! Switch off, remove plug from mains be-
fore adjusting, cleaning or if cable is cut, dam-
aged or entangled.
Your pressure washer requires an earth connection. The op-
erating voltage is 220-240 V AC/50 Hz or 220-230 V AC/
60 Hz according the product number indicated on the type
Bosch Power Tools
GHP 5-14
3 600 J10 1..
kW
°C
l/min
MPa
MPa
l/min
MPa
N
dB(A)
dB(A)
dB(A)
dB(A)
2
m/s
2
m/s
kg
See serial number (rating plate) on pressure washer.
plate. Do not connect a 60 Hz designed product to a 50 Hz
supply and vice versa. Only use approved extension cables.
Contact your Bosch Service Centre for details
Figure
1
220 V – 240 V/50 Hz
2
3 600 J10 0F0
3 600 J10 0L0
3
3 600 J10 0K0
4
3 600 J10 000
5
3 600 J10 070
If you want to use an extension cable when operating your
6
high pressure washer, only the following cable dimensions
7
should be used:
8
2
– 2.5 mm
– max length 20 m
2
9
– 4.0 mm
– max length 50 m
10
Note: If an extension cable is used it must be earthed and con-
nected through the plug to the earth cable of your supply net-
work in accordance with prescribed safety regulations.
If in doubt contact a qualified electrician or the nearest Bosch
Service Centre.
WARNING! Inadequate extension cables can be
dangerous. Extension cable, plug and socket
must be of watertight construction and intended
for outdoor use.
Cable connections should be kept dry and off the ground.
English | 5
GHP 6-14
3 600 J10 2..
2.4
2.6
50
50
8.3
10.5
14
14
15
15
8.3
10.5
1
1
22.98
32.24
Class F
Class F
IPX5
IPX5
l
Ω
Ω
84.5
82.5
3
3
92
90
3
3
4.91
4.91
1.5
1.5
23.4
25.6
/I
/I
220 V – 230 V/60 Hz
3 600 J10 1B0
3 600 J10 1P0
3 600 J10 2B0
1 609 92A 3EM | (9.11.16)