Unit Start-Up - Lennox EL195UH040NE36B Installation Instructions And Use

Elite el195uhne series gas furnace, upflow / horizontal air discharge
Hide thumbs Also See for EL195UH040NE36B:
Table of Contents

Advertisement

INTEGRATED CONTROL
(Automatic Hot Surface Ignition System)
RED LED
RECALL BUTTON
Figure 61
TABLE 10
1/4" QUICK CONNECT TERMINALS
120HUM
Humidifier 120VAC
LINE
120VAC
XFMR
Transformer 120VAC
CIRC
Indoor blower 120VAC
EAC
Indoor air quality accessory 120VAC
NEUTRAL
Common 120VAC
HUM24
Humidifier 24VAC
3/16" QUICK CONNECT TERMINALS
COOL
Cooling tap 24VAC
HEAT
Heating tap 24VAC
FAN
Continuous blower 24 VAC
PARK (no power)
Park terminal for speed taps
FLAME / FS
Flame Sense
24 COM
Common 24VAC
BLOWER OFF DELAY
Page 41
Electrical
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING
Do not use this furnace if any part has been underwater.
A flood-damaged furnace is extremely dangerous.
Attempts to use the furnace can result in fire or explosion.
Immediately call a qualified service technician to inspect
the furnace and to replace all gas controls, control
system parts, and electrical parts that have been wet or
to replace the furnace, if deemed necessary.
WARNING
Danger of explosion. Can cause injury or
product or property damage. If overheating
occurs or if gas supply fails to shut off, shut
off the manual gas valve to the appliance
before shutting off electrical supply.
CAUTION
Before attempting to perform any service or maintenance,
turn the electrical power to unit OFF at disconnect switch.
BEFORE LIGHTING the unit, smell all around the furnace
area for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the floor.
The gas valve on the EL195UHNE is equipped with a gas
control switch (lever). Use only your hand to move switch.
Never use tools. If the switch will not move by hand, do
not try to repair it. Force or attempted repair may result in
a fire or explosion.
Placing the furnace into operation:
EL195UHNE units are equipped with an automatic hot
surface ignition system. Do not attempt to manually light
burners on this furnace. Each time the thermostat calls for
heat, the burners will automatically light. The ignitor does
not get hot when there is no call for heat on these units.

Advertisement

Table of Contents
loading

This manual is also suitable for:

El195uh060ne36bEl195uh080ne48cEl195uh100ne60c

Table of Contents