Superior Fireplaces WRT3538WS Installation And Operation Instruction Manual page 14

Indoor wood-burning fireplace
Table of Contents

Advertisement

Terminations/Spark Arrestor
The fireplace system must be terminated with the listed round top or
chase terminations. In any case, refer to the installation instructions
supplied with the termination.
CAUTION: Do not seal openings on the rooftop
flashing. Follow the installation instructions provided
with the termination being used.
Stainless
Inner Flue
Pipe
Secure
Termination
to Outer
Pipe with 3
Screws
Overlap Shingles
(Top and Sides of
Flashing Base)
Figure 20 - Termination
CHASE INSTALLATIONS
Instructions for chase installations are included with the chase style
termination chosen. In a multiple chase installation, be sure to provide
adequate distance between terminations to prevent smoke spillage
from one termination to another. We suggest that terminations be
separated at least 24", center to center and stacked at a vertical height
difference of 18" (see Figure 21).
Note: If a decorative shroud is to be installed, contact the manufac-
turer for specifications.
24" (610 mm)
24" (610 mm)
Figure 21 - Multiple Chase Installation
14
VENTING INSTALLATION Continued
10 FOOT RULE
All flue gas outlet chimney terminations must extend a minimum of
3 feet in height above the highest point where it passes through the
roof and must be at least 2 feet above the highest point of the roof
that is within a horizontal distance of 10 feet (see Figure 22).
RLT-12D
Level of Flue
Gas Outlet
Waterproof
Caulking
Storm
Collar
Flashing
SQUARE TOP TERMINATIONS INSTALLATION STL-12D AND
STL-12DMP
1.
Underlap
Shingles
2.
(762 mm)
18" (458 mm)
Min. Typ.
SuperiorFireplaces.us.com
10'
(3.05 m)
2' (0.61 m) Min.
(0.91 m)
Min
Figure 22 - 10 Foot Rule
Construct chase as illustrated in Figure 23. Note: The shortest
vertical side must be at least 30" high and minimum inside di-
mension must be at least 19" as shown in Figure 23.
Add pipe sections to chimney system as outlined in fireplace
installation instructions until last piece of chimney is a maximum
of 6" below top of chase (see Figure 23).
(483 mm)
30"
Min.
Figure 23 - Constructing Chase
Level of Flue
Gas Outlet
10'
(3.05 m)
3'
2' (0.61 m)
Min.
19"
6" (153 mm) Max.
900855-00_B
3'
(0.91 m)
Min