6/12-12/12
45.0°
Figure 17 - Roof Opening Measurements
900855-00_B
VENTING INSTALLATION Continued
30" (762 mm)
1" (26 mm)
Min
Opening "A"
Opening "A"
Used Flashing
Max.
Model No.
17" (432 mm)
V6F-10DM
19" (483 mm)
V6F-10DM
24" (610 mm)
V12F-10DM
SuperiorFireplaces.us.com
FLASHING INSTALLATION (V6F-10DM OR V12F-10DM)
Determine the flashing to be used with the roof opening chart. Slide
flashing over pipe until base is flat against roof. Replace as many
Min.
shingles as needed to cover exposed area and flashing base. Secure
in position by nailing through shingles (see Figure 18). DO NOT NAIL
THROUGH FLASHING CONE.
Installing Flashing on a Metal Roof
When installing the flashing on a metal roof, it is required that putty
tape be used between the flashing and the roof. The flashing must be
secured to the roof using #8 x 3/4" screws and then sealed with roof
coating to prevent leakage through the screw holes. A roof coating
must also be applied around the perimeter of the flashing to provide
a proper seal.
Storm Collar
Flashing
Cone
Nail Only Outer
Perimeter of Flashing
Underlap Shingles at
Bottom
Storm Collar Installation (SC2-1)
Place storm collar over pipe and slide down until it is snug against
the open edge of the flashing (see Figure 19). Apply waterproof caulk
around the perimeter of the collar to provide a proper seal.
Chimney
Pipe
Storm
Collar
Overlap Shingles
Top and Sides Only
Figure 18 - Flashing Installation
Figure 19 - Storm Collar
Waterproof
Caulk
Flashing
13