Stopping the engine

If engine does not stop, close choke to stall engine.
Have your ECHO dealer inspect and repair.
NOTE
When misting liquid is over, stop the engine.
Do not keep engine running, chemical tank has been emptied.
Carburettor has been correctly adjusted in factory.
Do not readjust yourself unless it is necessary.
It should be readjusted be ECHO dealer.
1. Throttle lever
2. Stop button
Turn throttle lever to the lowest position and push stop button.

Filling chemical tank

NOTE
Be sure that valve is closed before starting engine.
1. Chemical tank cap
2. Liquid vaive
Close liquid valve.
Fill liquid chemical through filter into tank.
Stir up after filling to avoid chemical deposits at bottom of tank.

For safe operation

1. Secure the chemical tank cap.
2. Check all connections to avoid chemical leak. (nozzle, nozzle pipe, hose etc.)
3. Avoid wearing loose clothing and always wear safety glasses and gloves.
4. Use a face filter mask to avoid breathing chemical.
5. Check wind direction before spraying.
6. Do not point nozzle in the direction of people.
7. Stop the engine when refueling and / or replacing parts.
8. Close chemical liquid valve when not in use.
9. Avoid using at engine speeds where the clutch slips.

Spraying

NOTE
Since this unit is equipped with a centrifugal clutch, sprinkling not possible when the engine
is running at low speeds (idling).
Ensure that chemical liquid valve is closed before starting engine.
After engine is warmed up, turn throttle lever to the high speed position (Upper position) and
open liquid valve.