Routing cables; connecting and installing bus connectors
5.3.1
Connecting bus cable to bus connectors with order number
6ES5 ...
Preparing the bus
cable
Connecting
conductors
5-20
To connect the bus cable to a bus connector with order number 6ES5 ...,
proceed as follows:
1. Strip the ends of the cable conductors as shown in Fig. 5-8.
6XV1 830–0AH10/-3BH10
11
11
Figure 5-8
Stripping the cable for connection to bus connector (6ES5 ...)
2. To open the housing of the bus connector, slacken the securing screws and
lift off the cover.
There are two ways of connecting the conductors to the bus-connector
terminals:
Connect or disconnect the conductors one at a time, using a screwdriver
Connect or disconnect both conductors simultaneously, using the release
tool enclosed with the bus connector.
Press with screwdriver (1) to
engage or disengage the
conductor (2).
Figure 5-9
Connecting the conductors to the bus connector (6ES5 ...)
6XV1 830–3AH10
6
Press with release tool (1) to open both
contacts simultaneously so that conductors
(2) can be connected or disconnected.