4.10 Receiver Section

Item
Condition
Panel tuning mode
1.
[Panel test mode]
AF level
1) CH-Sig: 1-1
setting
SSG output:
-47dBm (1mV)
(MOD: 1kHz/
±1.5kHz)
2. RSSI
1) Adj item:
refer-
[An RRSSI]
ence
Adjust:[***]
2) Adj item:
[Frequency:
700MHz Band]
[RX/TA Low]→
[RX/TA Center]→
[RX/TA High]
[Frequency:
800MHz Band]
[RX/TA Low]→
[RX/TA Center]→
[RX/TA High]
SSG output:12dB
SINAD level -3dB
(MOD:1kHz/
±1.5kHz)
3. Open
1) Adj item:
Squelch
[Aw SQL]
Adjust:[***]
[Analog
2) Adj item:
Wide
[Frequency:
5k]
700MHz Band]
[RX/TA Low]→
[RX/TA Center]→
[RX/TA High]
[Frequency:
800MHz Band]
[RX/TA Low]→
[RX/TA Center]→
[RX/TA High]
SSG output:12dB
SINAD level at
Analog Narrow
-3dB (MOD:1kHz/
±3kHz)
Measurement
PC test mode
Test-
equip-
ment
1) Test Channel
SSG
Channel: 1
DVM
Test Signaling
AF
Mode: Analog
VTVM
Signaling: 1
Dummy
SSG output:
load
-47dBm (1mV)
(MOD:1kHz/
±1.5kHz)
1) Adj item:
SSG
[RSSI Reference
Distor-
(Analog Narrow)]
tion
2) Adj item:
meter
[Frequency:
Oscillo-
700MHz Band]
scope
[RX/TA Low]→
[RX/TA Center]→
[RX/TA High]
[Frequency:
800MHz Band]
[RX/TA Low]→
[RX/TA Center]→
[RX/TA High]
SSG output:12dB
SINAD level -3dB
(MOD:1kHz/
±1.5kHz)
1) Adj item:
SSG
[Open Squelch (An-
Distor-
alog Wide 5k)]
tion
2) Adj item:
meter
[Frequency:
Oscillo-
700MHz Band]
scope
[RX/TA Low]→
[RX/TA Center]→
[RX/TA High]
[Frequency:
800MHz Band]
[RX/TA Low]→
[RX/TA Center]→
[RX/TA High]
SSG output:12dB
SINAD level at
Analog Narrow
-3dB (MOD:1kHz/
±3kHz)
Unit
Ter-
Unit
Parts
minal
Panel ANT
Panel Vol-
Uni-
ume
versal
knob
con-
nector
Panel ANT
Panel
Uni-
versal
con-
nector
Panel ANT
Panel
Uni-
versal
con-
nector
Adjustment
Method
Turn the Volume knob to
obtain 0.90V AF output.
[Panel tuning mode]
After input signal from
SSG, press [
] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
[Panel tuning mode]
After input signal from
SSG, press [
] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
(No.RA016<Rev.001>)1-59
Specifi-
cations
/Remarks
0.90V
±0.1V