Lincoln Electric K2613-5 Operator's Manual page 16

Table of Contents

Advertisement

CV OPERATION
Maximum WFS
Minimum Arc
(Standard
Volts
Torque)
15 V
400
17 V
450
21 V
570
24 V
650
27 V
700
Wire Feed Speed, CC Operation
When Across the Arc models are operated with CC
power sources, the wire feed speed changes as the arc
voltage changes. When the arc voltage increases, the
wire feed speed will increase; and when the arc voltage
decreases, the wire feed speed will decrease.
English
To preset the wire feed speed on CC power sources:
1. Set the Wire Feed Mode switch inside the LN-25™
Maximum WFS
Pro to "CC".
(Extra Torque )
2. Refer to the Figure 10 graph for the setting for the
wire feed speed knob setting. Select the horizontal
220
line representing the Desired Wire Feed Speed. (See
250
Figure 10 arrow for 375 in/min.)
300
3. Select the diagonal line representing the Arc Volts.
350
(See Figure 10 for 29 volts.)
400
4. Determine the vertical line representing the CC
representing the CC Wire Feed Speed setting where
the above two lines cross. (See Figure 10 arrow line
for 450.) Set the LN-25™ Pro wire feed speed knob
to this value.
CC WFS dial setting =
Example:
=
=
(See Figure 10)
Figure 10
13
desiredWFSx35
Arc Volts
375in/min.(HorizontalLine)x35
29 Arc Volts (Diagonal Line)
452.5 (Vertical Line)
Use 450 setting
A constant voltage (CV) power
source is recommended for
fluxcored arc welding. (FCAW) and
gas metal arc welding (GMAW) to
obtain code qual i ty resul ts.
However, this wire feeder may also
be used with a constant current (CC)
power source to obtain passable
results for noncritical quality
applications.
English

Advertisement

Table of Contents
loading

This manual is also suitable for:

K2613-7Ln-25 pro

Table of Contents