Listings And Code Approvals; Ratings Label - Quadra-Fire DV400S Owner's Manual And Installation Instructions

Direct vent room heater
Table of Contents

Advertisement

DV400S DIRECT VENT ROOM HEATER
LISTING & CODE APPROVALS
U.S. CERTIFICATION
The DV400S Series Room Heater has been tested in accordance with the
ANSI standard Z21.88 1998 and UL307B and has been listed by OMNI-
Test Labs for installation and operation as described in these installation
and operation instructions. All components are A.G.A. or UL safety
certified.
Canada Certification
The DV400S Series Room Heater has been tested in accordance with
CSA 2.33-M98 and has been listed by OMNI-Test Labs for installation and
operation as described in these installation and operating instructions. All
components are C.G. A. or C.S.A. safety certified.
Listed by
O -T L
Beaverton
Oregon USA
C
OMNI-Test Laboratories, Inc.
Report No. / Rapport Numero
061-S-22-4
APPROVED FOR CANADA AND USA TO: ANSI Z21.88-1998 / CSA 2.33-M98 Vented Gas Fireplace Heaters, and applicable sections of UL307b Gas Burning Heating Appliances for
Manufactured Homes and Recreational Vehicles, CAN/CGA 2.17-M91 "Gas Fired Appliances for use at High Altitudes." This appliance is manufactured for operation with Natural Gas.
For conversion to propane Manufacturer's Part
thermostat installation is required.
APPROUVÉ POUR LE CANADA ET LES ÉTATS-UNIS: ANSI Z21.88-1998 / CSA 2.33-M98 Fournaises au Gaz avec Ventilation, et les sections applicables de UL 307b Appareils de
Chauffage Au Gaz pour les Maisons Mobiles et les Véhicules Motorisés, CAN/CGA 2.17-M91 "Gas Fired Appliances for use at High Altitudes". Cet appareil est manufacturé pour
l'opération avec le Gaz Naturel. Pour une conversion au gaz propane les pièces du Manufacturier #844-8240 et ses instructions doivent être utilisées. Cet appareil peut être utilisé
dans une chambre à coucher ou salle de séjour; au Canada, l'installation d'un thermostat à distance est exigée.
Input Rate on "HI" (BTU/Hr)
Puissance Évaluée à "HI" (BTU/Hr)
Input Rate on "LO" (BTU/Hr)
Puissance Évaluée à "LO" (BTU/Hr)
Maximum Output (BTU/Hr)
Puissance Maximum (BTU/Hr)
Main Burner Orifice
Orifice du Brûleur Principal
Minimum Inlet Pressure (Inches W.C.)
Pression Minimum de la Valve (pouces W.C.)
Maximum Inlet Pressure (Inches W.C.)
Pression Maximum de la Valve (pouces W.C.)
Manifold Pressure on "HI" (Inches W.C.)
Pression du Collecteur d' Échappement à "HI" (pouces W.C.)
This appliance equipped for altitudes 0-2000' (0-610m) in USA; and in Canada for altitudes of 0-4500' (0-1370m). In USA for Altitudes above
2000', the vent configuration, orifice, or combination of both may need to be changed. See Owner's Manual for information on making these
changes. Cet appareil est équipé pour les altitudes de 0-2000' (0-610m) aux États-Unis; et au Canada pour les altitudes de 0-4500' (0-1370m).
Pour les altitudes au dessus de 2000' aux États-Unis, la configuration du ventilateur, son orifice ou les deux peuvent possiblement avoir à être
changé. Voyez le manuel du propriétaire pour les informations sur ces changements.
This appliance must be installed in accordance with local codes, if any; if none, follow ANSI Z223.1 in USA, CAN 1-B149 in Canada.
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located,
manufactured (mobile) home where not prohibited by local codes. See owner's manual for details. This appliance is not convertible for use with other
gases, unless a certified kit is used. Cet appareil doit etre utilise uniquement avec le type de gaz indique sur la plaque signaletique et peut etre installe
dans une maison prefabriquee (mobile) installee a demeure si les reglements locaux le permettent. Voir la notice du proprietaire pour plus de details. Cet
appareil ne peut etre converti a d'autres gaz sauf si une trousse de conversion certifiee est utilisee.
This appliance must be properly connected to a venting system in accordance with the manufacturer's installation instructions. If venting is disconnected
for any reason, the vent-air intake system must be properly resealed and reinstalled.
Cet appareil doit ê correctement raccordé á un système d'évacuation, conformément aux instructions du fabricant.
Keep burner and control compartment clean. See installation and operating instructions accompanying this appliance. Gardez le brûleur et le
compartiment de contrôle propres. Vérifiez les instructions d'installation et d'opération qui accompagnent cet appareil. This vented gas fireplace heater
is not for use with air filters. / Cet appareil de chauffage au gaz n'est pas pour l'usage avec des filtres d'air
DO NOT REMOVE THIS LABEL /
NE PAS ENLEVER L'ÉTIQUETTE
2001
March 4, 2002
SERIAL/RATING LABEL
MODEL / MODELE: DV400S VENTED GAS FIREPLACE HEATER
FOURNAISE AU GAZ AVEC VENTILATION
NOT FOR USE WITH SOLID FUEL /
NE PAS UTILISER AVEC LE COMBUSTIBLE SOLIDE
#844-8230
and instructions must be used. This appliance may be installed in a bedroom or bedsitting room; in Canada remote
FAN TYPE VENTED CIRCULATOR / VENTILATEUR CIRCULATOIRE Opt. Blower Part #844-0150
Blower Electrical Rating / Évaluation du Ventilateur Électrique: 115 V., 1.5 Amps, 60 Hz, 150 Watts
Thermal Efficiency / Efficacité Thermique 77% NG
For use with Natural Gas
Usage Au Gaz Naturel
0-4500'
29,500
19,500
22,700
.106/2.69 DIA./mm
4.5"
7.0"
3.5"
Date of Manufacture / Date du Manufacturier
2002
2003
Jan
Feb
Mar
This Heater is approved for installation in bedrooms and mobile
homes in the United States and Canada.
L
ocal Codes
This installatin must conform with local codes or, in the absence of local codes,
with theNational Fuel Gas Code, ANSI Z223.1-latest edition, in the U.S.A. and the
CAN/CGA B149-latest edition, in Canada.
Efficiency
The efficiency rating of the appliance is a product thermal efficiency
rating determined under continuous operating conditions and was determined
independently of any installed system.
For use with Propane
Usage Au Gaz Propane
0-4500'
28,500
24,000
22,500
.063/1.60 DIA./mm
11"
14"
10"
Apr
May
Jun
Jul
Aug
Page 5
SERIAL NO.
A Division of Hearth Technologies Inc.
1445 North Highway Colville,
WA 99114
Made in U.S.A. /
Fait Aux États-Unis
Sep
Oct
Nov
Dec
R
250-5911
30211C