Opop H 418 Manual

Opop H 418 Manual

Wood pellets burner
Hide thumbs Also See for H 418:

Advertisement

Wood Pellets Burner

Content list:

Site 2:
Site 3:
Site 4:
Site 5:
Site 6-11:
USER GUIDE
Site 12:
EXTENDED SET-UP GUIDE
Site 13:
CLEANING GUIDE
Site 14:
MAINTAIN GUIDE
Site 15:
Site 16-17:
Site 18:
Site 19:
WARANTY
Site 20:
Site 21:
Side 22:
EC DECLARATION OF CONFORMITY
EN 303-5 approved by DTI (Danish Technological Institute)
Approved for pressure expansion
Energy class AA
Version 6

Advertisement

Table of Contents
loading

Summary of Contents for Opop H 418

  • Page 1 Wood Pellets Burner Version 6 Content list: Site 2: INSTALLATION GUIDE FOR OPOP BOILER Site 3: INSTALLATION GUIDE FOR OPOP / NBE BOILER Site 4: BOILER INSTALLATION GUIDE Site 5: SETTING BY WEIGHT Site 6-11: USER GUIDE Site 12: EXTENDED SET-UP GUIDE...
  • Page 2 Manual NBE pellet system INSTALLATION GUIDE FOR OPOP BOILER OPOP H 418 H 430 H 440 H 460 Comfort A Height 1005 1025 1105 1145 B Depth C Width without burner D Height smoke pipes E Height Returns F Height Output...
  • Page 3 Manual NBE pellet system INSTALLATION GUIDE FOR OPOP / NBE BOILER NBE / OPOP 30 S 60 M 80 L A Height 1142 1272 1272 B Depth 1003 C Width without burner D Height smoke pipes E Height Returns F Height Output...
  • Page 4 Manual NBE pellet system BOILER INSTALLATION GUIDE Installing into boiler: Check that the burner is undamaged. Fit the burner and tighten it firmly using the two wing nuts supplied. Ensure that the burner is in a horizontal position and all connections are tight. Fit the cover and the plug.
  • Page 5 Manual NBE pellet system SETTING BY WEIGHT Unplug the burner and force-run the auger until pellets start to come out of it, continue for 15 minutes. Then weigh the amount of pellets after 360 seconds and enter the result into the controls as the capacity of the auger.
  • Page 6 Manual NBE pellet system USER GUIDE There can be 3 run mode to see in the display You change by pressing up / down RUN MODE 1: Boiler temp./ Smoke temp. / Hot water temp. Return temp./ Tank content / Light sensor / Kwh / Clock mode. Circulation Pump / 3 way valve.
  • Page 7 Manual NBE pellet system USER GUIDE ACTUAL CONTENT Temperature Adjusting the content of the magazine. Magazine RESET CONSUMPT. Putting the pellets kg counter to zero. Auto combustion Man. combustion Timer Cleaning / power O2 Control SCREW CAPACITY Temperature After setting the auger performance in 360 seconds the control will Magazine automatically calculate the amount of pellets in low power and high power, pellets in pause , and pellets for ignition...
  • Page 8 Manual NBE pellet system USER GUIDE CLOCK Temperature Setting the clock. Magazine PERIOD HEATING HH:MM Setting the running time, when clock is starting the burner. Auto combustion 1.START HEATING HH:MM Starts the burner at this time , running time will be “period heating” Man.
  • Page 9 Manual NBE pellet system USER GUIDE NOTE: When using the O2 controller, 6 Minutes of pellets must be weighted and inserted in screw capacity. O2% MIN POWER Temperature The amount of excess oxygen in the smoke at low performance. Magazine Sets the amount of fuel so that the excess oxygen is at the required amount.
  • Page 10 Manual NBE pellet system USER GUIDE Ignition O2 SENSOR TUNE Calibration of oxygen sensor to ensure it gives accurate readings. Pause Hold the exhaust gas oxygen sensor in the air and calibrate it to give it a reference value to the air (21% oxygen). If the sensor by mistake don’t calibrate between 10 and 40 it cant be turned on.
  • Page 11 Manual NBE pellet system USER GUIDE Ignition BURNER TEMP. MAX Indicates the maximum temperature the burner can reach; protects against back Pause combustion. BOILER TEMP. MIN. Indicates the minimum temperature of the boiler ,before the control box monitors, Fine tune that boiler temperature raise again, if the temperature fails to raise in 10minutes triggers the alarm COLD BOILER.
  • Page 12 Manual NBE pellet system EXTENDED SET-UP GUIDE SETTING THE CONTROLS The controls work in 100 step modulation and change these step automatically. If you use the automatic calculation program after measuring the performance of the auger, no further setting should be necessary. Setting pellets at low and full load…...
  • Page 13 Manual NBE pellet system CLEANING GUIDE When cleaning, turn off the burner… Turn off the controls (hold the on/off button down for 10 seconds) and let the burner cool down for about 3 minutes, when it is completely switched off the burner is ready to be cleaned. Unplug the burner, remove the cover and the drop shaft, and unscrew the burner from the boiler before continuing.
  • Page 14 Manual NBE pellet system MAINTAIN GUIDE To make sure that you get an good experience with an pellets burner it is important that you maintain it correct. Every required year year Cleaning the burner head, if there is hard ashes. Cleaning below the burner grate for dust and ashes.
  • Page 15: Troubleshooting

    Manual NBE pellet system TROUBLESHOOTING Problem Cause Solution ALARM 1. Cinders/ash in the combustion head. Clean the combustion chamber! HOT DROP SHAFT 2. Ash in the boiler, smoke pipe and chimney. Clean the boiler, smoke pipe and chimney! OR BACK SMOKE 3.
  • Page 16 Manual NBE Pellets Systems ELECTRICAL WIRING DIAGRAMS...
  • Page 17 Manual NBE Pellets Systems ELECTRICAL WIRING DIAGRAMS PE-N-L Power to controlbox POWER AUGER PE-N-L1 External auger BLOWER PE-N-L2 PE-N-L3 Internal auger INT. AUGER PE-N-L4 IGNIGTION EKSTRA 1 PE-N-L5 Pump, hotwater valve , compressor cleaning EKSTRA 2 PE-N-L6 Pump, hotwater valve , compressor cleaning V+, TX, RX, V- Intelligent motor print Water flowmeter...
  • Page 18 Manual NBE Pellets Systems ACCESSORIES There can be coupled a different types of extra equipment to the burner Smoke temperature: Part. No. 180503 Get an reading on the control box. O2 regulation: Part. No. 100701 The burner adjusting the fan according to the feed of pellets. Outside temperature sensor: Part.
  • Page 19 Manual NBE Pellets Systems WARANTY All products purchased from NBE are naturally covered by the applicable Danish purchasing law. Products come with a two-year warranty valid from the date of receipt. However, this does not cover the exhaust gas oxygen sensor, electrical ignition or the combustion grate. These are considered to be replaceable parts.
  • Page 20 Manual NBE Pellets Systems MOUNTING THE PELLET HOPPER...
  • Page 21 Manual NBE Pellets Systems EXCEPTION FOR PRESSURE EXPANSION Jannich Hansen Brinken 10 DK 9830 Oester Vraa Landskronegade 33 2100 Copenhagen Telephone 39152000 www.arbejdstilsynet.dk Your contact JH Our ref. 20030027413 Our contact. G.Agersnap Direct telephone 0045-3915265915 Re: Use of burner to burn wooden pellets type Woody, Scotte, Bio-comfort and Boink in boiler equipment in relation to smaller, closed facilities in compliance with Work Supervisor Regulations for Hot-water Heating Systems.
  • Page 22 Manual NBE Pellets Systems EC DECLARATION OF CONFORMITY...

This manual is also suitable for:

H 430H 440H 460Comfort