Installation And Connection - Beko BFC621MB1 User Manual

Table of Contents

Advertisement

Installation and connection
Product can only be installed and connected in
accordance with the statutory installation rules.
Do not install the product next to refrigerators
1
or freezers. The heat emitted by the product
--•vvill increase the energy consumption of
cooling appliances.
Carry the product with at least two persons.
Product must be placed directly on the floor. It
must not be placed onto a base or a pedestal.
Electrical connection
Connect the product to a grounded outlet/line
protected by a fuse of suitable capacity as stated in
the "Technical specifications" table. Have the
grounding installation made by a qualified electrician
while using the product with or without a transformer.
Tt1e manufacturer shall not be liable for any damages
that will arise due to using the product without a
grounding installation in accordance with the local
regulations.
IDANGER:
\The product must be connected to the mains
supply only by an authorised and qualified
person. The product's warranty period starts
only after correct installation.
Manufacturer shall not be held responsible for
damages arising from procedures carried out
by unauthorised persons.
ANGER:
he power cable must not be clamped, bent or
rapped or come into contact with hot parts of
the product.
A damaged power cable must be replaced by
a qualified electrician. Otherwise, there is risk
of electric shock, short circuit or fire!
The mains supply data must correspond to the data
specified on the type label of the product. The rating
plate is either seen when the door or the lower cover is
opened or it is located at the rear wall of the unit
depending on the unit type.
Power cable of your product must comply with the
values in "Technical specifications" table.
HDANGER:
Before starting any work on the electrical
installation, disconnect the product from the
mains supply.
There is the risk of electric shock!
Connecting the power cable
1.
If a power cable is not supplied together with
your product,a
power cable that you would select
from the table (Technical specifications, page 13)
in accordance with the electrical installation at
your home must be connected to your product by
following the instructions in cable diagram.
If it is not possible to disconnect all poles in the supply
power, a disconnection unit with at least 3 mm contact
clearance (fuses, line safety switches, contactors)
must be connected and all the poles of this
disconnection unit must be adjacent to (not above) the
product in accordance with lEE directives. Failure to
obey this instruction may cause operational problems
and invalidate the product warranty.
2. Open the terminal block cover with a screwdriver.
3. Insert the power cable through the cable clamp
below the terminal and secure it to the main body
with the integrated screw on cable clamping
component.
4. Connect the cables according to the supplied
dia ram.
L
N
E--l(t31
220/230/240V
A~
3NAC 380/400/415 V
2NAC 380/400/415 V
5. After completing the wire connections, close the
terminal block cover.
6. Route the power cable so that it will not contact
the product and get squeezed between the
roduct and the wall.
15/EN