Service Manual
Removing the fan assembly
1.
Remove the panel plate.
2.
Remove the hex nut fi xing the fan, and then remove the fan.
Figure 74
3.
Unfi x the hooks and then open the electronic control box cover.
Figure 75
compressor
Motor
Electronic expansion valve
Figure 76
Bosch Thermotechnology Corp. | 02.2018
T3,T4,T5 sensor
Reversing valve
Bosch Climate 5000 AA Series Split Type Ductless Air Conditioner / Heat Pump | 59
4.
Disconnect the connector for fan motor from the electronic control board.
Figure 77
5.
Remove the four fi xing screws of the fan motor. Then remove the fan motor.
Figure 78
Data subject to change