Service Manual
Step3: Press the locker A and B (Fig. 65), to loosen the indoor from the
installation plate.
Step4: Unfold the supporter of Installation plate, then let it to hold the
indoor unit, helpful to do pipe connection in the back.
Figure 47
Bosch Thermotechnology Corp. | 02.2018
Bosch Climate 5000 AA Series Split Type Ductless Air Conditioner / Heat Pump | 51
9.1.4 How to Remove the panel assembly
Step1: Open the screw caps A and B (Fig. 66), remove the two screws.
Step2: Open the panel assembly, loosen the display board connector.
Figure 48
Step3: Pull the panel assembly along the direction indicated in Fig. 67 to
remove it.
Figure 49
Data subject to change