AT&T DLC-100 User Manual page 59

Digital life controller
Table of Contents

Advertisement

CP-01-2010 Supported Features for False Alarm
Reduction
Digital Life
CP-01
Feature
Feature
Name
Name
Abort Delay
Abort Window
– for Non-Fire
Zones
(Windows)
Abort
Abort
Sound
Annunciation
Cancel
Cancel
Sound
Annunciation
Cross
Cross Zoning
Zoning
Swinger
Swinger
Shutdown
Shutdown
Trips
Digital Life User Manual
Settings
Enabled/Disabled
with a range of
zero (0) to forty-
five (45) seconds
Enabled/Disabled
Enabled/Disabled
Enabled/Disabled
with a range of
one (1) to thirty
(30) seconds
Enabled/Disabled
with one (1) to six
(6) trips
|
Page 49 of 62
Default
Setting
Feature Description
Enabled
The Abort Delay feature is the time
with thirty
delay between when an alarm has
(30)
been triggered locally and when the
second
alarm is actually sent to the AT&T
delay
Digital Life Central Monitoring
Center. The Abort Delay feature
enables you time to enter your Alarm
Panel PIN into a keypad in order to
disarm the system and cancel the
alarm before it is reported to the
AT&T Digital Life Central Monitoring
Center.
NOTE: Consult with your Digital Life
Technician to determine if your
system is configured with a
communicator delay (Abort Delay).
An Abort Delay will prevent a report
to the AT&T Digital Life Central
Monitoring Center if your DLC-100 is
disarmed within thirty (30) to forty-
five (45) seconds after an intrusion
alarm is triggered. Note that fire-type
alarms are normally reported without
a delay.
Enabled
The Abort Sound feature generates
one (1) long beep from the keypad
when you abort an alarm during the
Abort Delay Time interval.
Enabled
The Cancel Sound feature generates
two (2) long beeps from the keypad
when you cancel an alarm.
Disabled
Cross zoning is a configuring of logic
within the alarm panel such that two,
or more, zones of the security
system are interdependent in
causing an alarm. This feature is set
per device and disabled by default.
Enabled
Swinger Shutdown is a false alarm
with two
prevention feature that counts the
(2) trips
number of alarms caused by a
specific intrusion device. The system
will auto-bypass a specific intrusion
device based on the swinger
shutdown count setting. After a
ATT-UM-V1.1-201303