On/Off Power Switch (Dsi); Thermostat & Eco Assembly; Dsi Circuit Board; Electrode - Suburban SW10P Service Training Manual

Hide thumbs Also See for SW10P:
Table of Contents

Advertisement

ON/OFF SWITCH ASSEMBLY
1. Switch that supplies 12 VDC to water heater.
2. Illuminating light to show no ignition.
1. A surface mount device that regulates water temperature at a preset temperature.
2. High temperature limit (E.C.O.) used as a re-setable cut-off device.
3. Controls voltage to module board
THERMOSTAT AND LIMIT SWITCH
MODELS: SW6D, SW6DE, SW6DEM, SW10D,
SW10DE, SW10DEM, SW12DEM
12 V.D.C. T-STAT
HI-LIMIT
120 Degree (ID# 3213) Not Available
130 Degree (ID# 2116) Standard (ID# 31254)
140 Degree (ID# 2476) Optional (ID# 312527)
DIRECT SPARK IGNITION
MODULE BOARD
1. An electronic panel that produces high voltage
spark ignition source.
2. Produces current to open gas valve coils.
3. Recognizes flame sense current.
4. Three trials for ignition.
ELECTRODE ASSEMBLY
1. A device that conducts high voltage to produce
spark.
2. Achieves micro amp signal to create flame sense
current.
Micro Amp Value: 3.0 or higher
THERMOSTAT AND ECO SWITCH
RESET BUTTON
THERMOSTAT AND LIMIT SWITCH
MODELS: SW6PE, SW6PER, SW6DE, SW10PE,
SW10PER, SW10DE, SW12DE
120 Degree (ID# 3212) Not Available
130 Degree (ID# 2306) Standard (ID# 312155)
140 Degree (ID# 2475) Optional (ID# 312153)
12 V.D.C.
1.0 AMP DRAW
21
WATER HEATER
ON
RESET
RESET BUTTON
120 V.A.C. T-STAT
HI-LIMIT