Removing The Liner Protectors - Siemens SITRANS F M MAG 3100 Operating Instructions Manual

Electromagnetic flowmeters
Hide thumbs Also See for SITRANS F M MAG 3100:
Table of Contents

Advertisement

CAUTION
Abrasive liquids / liquids containing solid particles
A vertical installation minimizes wear and deposits in the sensor
NOTICE
Gas/air bubbles in the liquid
A vertical installation minimizes any negative effect of gas/air bubbles in the liquid
● Horizontal installation, terminal box upwards or downwards
Figure 4-4
CAUTION
Do NOT mount the sensor with the terminal box sideways
This will position the electrodes at the top where there is possibility for air bubbles and at
the bottom where there is possibility for mud, sludge, sand etc.
NOTICE
Empty pipe detection
For applications with empty pipe detection, the sensor can be tilted 45°, as shown above.
4.4

Removing the liner protectors

CAUTION
Sensors with PTFE or PFA liners only!
The following information in only relevant for sensor types with PTFE or PFA liners!
SITRANS F M MAG 3100
Operating Instructions, 06/2010, A5E03005599-01
Horizontal installation, various terminal box positions
Installing/Mounting
4.4 Removing the liner protectors
25