Siemens RUGGEDCOM RS416 Installation Manual page 26

Hide thumbs Also See for RUGGEDCOM RS416:
Table of Contents

Advertisement

Chapter 3
Communication Ports
Serial DB9 Port
Figure 22: Serial DB9 Port Pin Configuration
a
The DSR, DCD and DTR pins are connected together internally.
b
In RS232 DCE mode, ports transmit to DTE devices on pin 2 and receive from DTE on pin 3.
c
RI is not connected.
NOTE
Pins 1, 4 and 6 and pins 7 and 8 are connected internally. In RS232 mode, these pins enter a high
impedance state. A DTE that asserts RTS will see CTS asserted. However, the device will not perform
hardware flow control.
Serial DB9 Port with IRIG-B Support
Figure 23: Serial DB9 Port Pin Configuration
d
In RS232 DTE mode, ports transmit to DTE devices on pin 2 and receive from DTE on pin 3.
20
5
1
9
6
5
1
9
6
Pin
RS232 DCE
a
1
DCD
b
2
TX
b
3
RX
a
4
DTR
5
Common (Isolated) Ground
a
6
DSR
7
RTS
8
CTS
c
9
RI
Shield
Chassis Ground
Pin
RS232 DTE
1
d
2
RX
d
3
TX
4
5
Common (Isolated) Ground
6
Common (Isolated) Ground
7
RTS
8
CTS
9
Common (Isolated) Ground
Shield
Chassis Ground
RUGGEDCOM RS416
Installation Guide
Mode
RS485
RS422
TX/RX+
TX+
RX+
RX-
TX/RX-
TX-
Mode
RS485
RS422
RX-
TX/RX+
TX+
RX+
IRIG-B+
TX/RX-
TX-
Serial Ports