Accumulator Tank - Winnebago Suncruiser 1999 Owner's Manual

Table of Contents

Advertisement

SECTION 7
PLUMBING SYSTEMS

ACCUMULATOR TANK

A pressurized accumulator tank is installed in
the water line directly upstream from the water
pump. The accumulator tank holds a small
amount of water under pressure of 20 psi to
reduce water line pulsation noise and pressure
variations when using the water pump system.
This also contributes to longer pump life, less
pump cycling, and less amperage draw by the
water pump from the coach batteries.
NOTE: The accumulator tank has a precharge
pressure which must be checked month-
ly and maintained at 20 psi for the sys-
tem to work properly.
Adjusting Precharge Pressure
A tire-type valve stem is provided on the end
or top of the accumulator tank to check or add
air pressure.
When adding air, do not exceed 20 psi tank
precharge pressure because you may risk ruptur-
ing the pressure bladder inside the accumulator
tank.
Because of the relatively small capacity of the
bladder, check pressure with a standard tire pres-
sure gauge before adding air, then if necessary,
add air in small bursts, checking pressure
between each burst until 20 psi is attained.
7-2
Overfilling will also push the bladder too far
and reduce the volume of water held in the accu-
mulator tank, making the system inefficient.
The precharge valve stem cap must be tight
to prevent pressure leak-down.
Further Information
See manufacturer's information supplied for
your motor home operation manual binder for
complete maintenance instructions and precau-
tions.
INSTRUCTIONS FOR DISINFECT-
ING OF FRESH WATER SYSTEMS
ON RECREATION VEHICLES
(As approved by the U.S. Public Health
Service)
To assure complete disinfection of your fresh
water system, it is recommended that the follow-
ing procedure be followed on a new system, one
that has not been used for a period of time, or
one that may have become contaminated. This
procedure is also recommended before long
periods of storage such as over winter.
1. Prepare a chlorine solution using 1 gallon of
water and 1/4 cup of household bleach
(sodium hypochlorite solution). With tank
empty, pour chlorine solution into the tank.
Use 1 gallon solution for each 15 gallons of
tank capacity. This procedure will result in a
residual chlorine concentration of 50 ppm in
the water system. If a 100 ppm concentration
is required as discussed in item 3, use 1/2
cup of household bleach with 1 gallon of

Hide quick links: