Océ ProCut
Compressed Air:
Compressed air is not supplied internally with the Océ ProCut cutter. The customer must supply
either house compressed air or an external air compressor that meets the following requirements:
Connector hose interior Ø
Air purity class (ISO 8573-1)
Air pressure
Air flow (minimum)
Basic unit
Pneumatic Oscillating Tool
Router Module
Notes:
•
Two separate compressed air connections are required if using the POT.
•
A Combination requires the highest pressure and the highest air flow. Example: Main unit + RM +
POT = 0.8 - 1.0 MPa and 300 - 400 l/min
Océ ProCut Site Preparation Guide - Revision: E
6 - 7 mm
4
Pressure
0.8 - 1.0 mPa
116 – 145 Psi
0.6 – 1.0 mPa
87 – 145 Psi
0.8 – 1.0 mPa
116 – 145 Psi
0.6 – 1.0 mPa
87 – 145 Psi
Table 11: Compressed Air
Site Prep
0.24 – 0.28 In
Air flow
300 L/min
79 Gal/min
19 L/min
5 Gal/min
300 – 400 L/min
79 – 106 Gal/min
40 L/min
10.6 Gal/min
10