Océ ProCut
Electrical connections - 400 V system with 2.2/2.55 kW vacuum pump (1600 M Only)
Comply with national instructions and laws at connection the cutter to the power supply system. The
cutter is connected with one power cord to the power supply system. The vacuum pump is
connected to the power box of the cutter. 1 power cord is included in the package content.
"A" Cutter Power box
Phases
Voltage
Power frequency, pump-depending
Power fusing min.
Wiring
CEE-Plug

Table 8: Electrical Connections with 2.2/2.55kW Vacuum Pumps

Electrical connections - 208 V system with 2.2/2.55 kW vacuum pump (1600 M Only
Comply with national instructions and laws at connection the cutter to the power supply system. The
cutter is connected with one power cord to the power supply system. The vacuum pump is
connected to the power box of the cutter. 1 power cord is included in the package content.
"A" Cutter Power box
Phases
Voltage
Power frequency, pump-depending
Power fusing min.
Wiring
CEE-Plug

Table 9: Electrical Connections with 2.2/2.55kW Vacuum Pumps

Océ ProCut Site Preparation Guide - Revision: E
Figure 4: 400V Electrical Connection

Figure 5: 200V Electrical Connection

Value
Unit
3
400
V
50/60
Hz
32
A
3 phases, L1, L2, L3, N, PE
32A
Value
Unit
3
208
V
50/60
Hz
32
A
3 phases, L1, L2, L3, N, PE
32A