4.4 Dealer calibration

The Dealer calibration procedure (see
following parameters to be set:

• User calibration on/off.

• Depth response.
• Boat show mode on/off.
Dealer calibration also gives access to the Factory defaults screen. This enables
you to re-apply the factory settings if you want to reset the instrument to a known
operating condition.
To commence Dealer calibration, hold down the depth and alarm keys together
for approximately 12 seconds, to select the Dealer calibration entry page. Press
the offset and reset keys together, to proceed with the calibration, then use the
depth
User calibration on/off
Use either the offset key or the reset key to switch the User calibration either
ON or OFF as required. With OFF selected, User calibration and Intermediate
calibration are both disabled. This feature is particularly useful aboard charter
vessels, to prevent unwanted alteration of calibration settings.

Response settings

The depth response value determines the frequency at which information is
updated. A low number provides a smooth response and a high number a much
livelier response.
Use the offset (decrement) and reset (increment) keys to set the required value.
Response values are from 1 to 15.

Boat show mode

CAUTION:
Do NOT enable this mode. It must only be used for demonstration
purposes.
Ensure that the Boatshow Mode Use is set to OFF. If necessary, use the offset or
key to achieve this.
reset
key to proceed from screen to screen as calibration progresses.